White Balance Adjustment

Carry out white balance adjustment when the illumination condition (color temperature) is changed. Adjust the white balance when using the camera for the first time or after replacing the lens.

1.In the MENU mode, set up WHITE BAL: MEM 3200K or MEM 5600K.

2.Turn off the MENU screen to select the DIRECT mode.

3.Provide a proper aperture value of lens using the auto iris function or manually.

4.Put an white object in the subject image, and zoom it up.

5.Hold the AWB button pressed for about 2 seconds for automatic white balance adjustment. With MESSAGE RTN:ON, AUTO WHITE appears. At the end of successful adjustment AUTO WHITE:OK appears.

Note:

If adjusted under a light source that has a flicker component, such as fluorescent or mercury, the white balance accuracy can be impaired. Change the electronic shutter mode (Sub-menu 1 Shutter or Variable) setting to reduce flicker before engaging the auto white balance adjustment.

6.If white balance adjustment cannot be made, any of the following messages will appear. Take a proper procedure according to the error message, and then try white balance adjustment again.

Error message

Procedure

AUTO WHITE:NG

Turn off the color bar.

CHANGE TO CAM

 

TRY AGAIN

 

AUTO WHITE:NG

Set up WHITE BAL:MEM 3200K or MEM 5600K.

CHANGE TO MEMORY MODE

 

TRY AGAIN

 

AUTO WHITE:NG

White balance cannot be made due to insufficient illumination.

LOW LIGHT

 

TRY AGAIN

Increase the intensity of illumination, turn lens iris toward open direction, or

 

increase the gain to provide a proper video level.

 

Press the AWB switch again.

AUTO WHITE:NG

White balance cannot be made due to excess illumination.

HIGH LIGHT

 

TRY AGAIN

Increase the intensity of illumination, turn lens iris toward closed direction,

 

or increase the gain to provide a proper video level.

 

Press the AWB switch again.

AUTO WHITE:NG

The color temperature is too high, making it impossible to reach the optimum

C.TEMP HIGH

value in adjustment. (If there is no problem in practical application, use the

TRY AGAIN

camera under the current condition.)

 

 

Add a filter to the lens or illumination to decrease the color temperature.

AUTO WHITE:NG

The color temperature is too low, making it impossible to reach the optimum

C.TEMP LOW

value. (If there is no problem in practical application, use the camera under

TRY AGAIN

the current condition.)

 

 

Add a filter to the lens or illumination to increase the color temperature.