Image 44

Application Files (APP-1,APP-2,APP-3)

Camera setting data can be stored in three application files. These enable optimizing the camera for specific scene and lighting conditions, then storing the setting data in memory for quick recall at the appropriate time.

The application files have been set at the factory as follows.

APP-1: Standard type camera settings

APP-2: General purpose surveillance and TV conferencing

APP-3: Microscope settings. Particularly the masking is suitable for good color reproduction with a light source of about 5000 K combined with a 9200 K color monitor.

Select the file according to the application. If the settings are changed for finer control, the setting data can be stored is each file.

1. Items saved to application files

The following items can b saved to each file. The factory data are shown.

Menu item

Application file

 

APP-1

APP-2

APP-3

 

MAIN MENU

 

 

 

 

 

WHITE BAL

MEM

MEM

MEM

 

3200K

3200K

3200K

GAIN

NORMAL

NORMAL

NORMAL

 

 

 

 

DTL

0

25

0

 

 

 

 

DNR

OFF

OFF

OFF

 

 

 

 

 

SUB MENU 1

 

 

 

 

 

M.BLACK

0

0

0

 

 

 

 

SHUTTER

OFF

OFF

AES

 

 

 

 

DTL FREQ

STANDA

STANDA

HIGH

 

RD

RD

 

 

SUB MENU 2

 

 

 

 

 

DYNA

OFF

ON

OFF

CHROMA

 

 

 

CHROMA

0

25

0

GAIN

 

 

 

AUTO

ON

ON

ON

KNEE

 

 

 

MASKING

ON

ON

ON

 

 

 

 

SHAD

COLOR

COLOR

LUMINAN

MODE

 

 

CE

 

LENS

 

 

 

 

 

LENS TYPE

VIDEO

VIDEO

DC

 

 

 

 

IRIS MODE

AUTO

AUTO

MANUAL

 

 

 

 

Menu item

Application file

 

 

APP-1

APP-2

APP-3

 

LEVEL

 

 

 

 

 

 

 

 

 

R GAIN

0

 

0

 

0

 

 

 

 

 

 

B GAIN

0

 

0

 

0

 

 

 

 

 

 

 

MASKING

 

 

 

 

 

 

 

 

 

R HUE

4

 

4

 

-8

 

 

 

 

 

 

Y HUE

-2

 

-2

 

-5

 

 

 

 

 

 

G HUE

-6

 

-6

 

-3

 

 

 

 

 

 

C HUE

-4

 

-4

 

0

 

 

 

 

 

 

B HUE

4

 

4

 

10

 

 

 

 

 

 

M HUE

16

 

16

 

-14

 

 

 

 

 

 

R SAT

-1

 

-1

 

-4

 

 

 

 

 

 

Y SAT

-3

 

-3

 

5

 

 

 

 

 

 

G SAT

9

 

9

 

-1

 

 

 

 

 

 

C SAT

14

 

14

 

12

 

 

 

 

 

 

B SAT

8

 

8

 

-16

 

 

 

 

 

 

M SAT

-6

 

-6

 

-6

 

 

 

 

 

 

31