3–42

“C” Group: Intelligent Terminal Functions

 

 

 

 

“C” Function

Run

 

Defaults

 

 

 

 

 

 

 

 

 

 

 

 

 

Func.

Name /

Description

Mode

–FE

–FU

–FR

Units

 

 

Edit

 

 

Code

SRW Display

(CE)

(UL)

(Jpn)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C_43

Arrival frequency

Sets the frequency arrival

0.0

0.0

0.0

Hz

 

 

 

setting for deceleration

setting threshold for the output

 

 

 

 

 

 

 

 

 

 

frequency during deceleration

 

 

 

 

 

 

 

 

ARV DEC

000.0Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C_44

PID deviation level

Sets the allowable PID loop

3.0

3.0

3.0

%

 

 

 

setting

 

error magnitude (absolute

 

 

 

 

 

 

 

 

 

 

value), SP - PV, range is 0.0 to

 

 

 

 

 

 

 

 

OV PID

003.0%

 

 

 

 

 

 

 

 

100%, resolution is 0.1%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C_81

O input span calibration

Scale factor between the

Factory-calibrated

 

 

 

 

 

external frequency command

 

 

 

 

 

 

 

 

ADJ-O

082

 

 

 

 

 

 

 

 

on terminals L – O (voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

input) and the frequency output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C_82

OI input span calibra-

Scale factor between the

Factory-calibrated

 

 

 

tion

 

external frequency command

 

 

 

 

 

 

 

 

 

 

on terminals L – OI (current

 

 

 

 

 

 

 

 

ADJ-OI

066

 

 

 

 

 

 

 

 

input) and the frequency output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C_91

Debug mode enable

(Reserved) DO NOT EDIT

00

00

00

Configuring ParametersDrive

 

 

 

 

 

 

 

 

 

 

 

 

INIT DEBG

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C_92

Core monitor address

(Reserved) DO NOT EDIT

0000

0000

0000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(not displayed)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C_93

Core monitor date

(Reserved) DO NOT EDIT

 

 

 

 

 

 

 

 

 

 

 

 

 

(not displayed)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C_94

Core set address

(Reserved) DO NOT EDIT

D_01

D_01

D_01

 

 

 

 

 

 

 

 

 

 

 

 

 

(not displayed)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C_95

Core set date

 

(Reserved) DO NOT EDIT

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

(not displayed)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Settings C_81 and C_82 are factory-calibrated for each inverter. Do not change these settings unless absolutely necessary. Note that if you restore factory defaults for all parameters, these settings will not change.