3–43

SJ100 Inverter

“H” Group: Motor Constants Functions

Introduction

The “H” Group parameters configure the

Inverter Torque Control Algorithms

inverter for the motor characteristics. You

 

 

 

 

 

 

 

 

 

00

 

A 44

 

 

must manually set H_03 and H_04 values to

V/f control,

 

 

 

 

 

 

 

 

 

match the motor. The remaining parameters

constant torque

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

are related to sensorless vector control (SLV),

 

01

 

 

 

Output

 

 

 

 

 

 

 

 

and are in use only when function A_44 is set

V/f control,

 

 

 

 

 

 

 

 

 

for SLV as shown in the diagram. The proce-

variable torque

 

 

 

 

 

 

 

dure in “Auto-tuning for Sensorless Vector

 

02

 

 

 

 

 

 

Sensorless vector

 

 

 

 

 

 

Control” on page 4–35 automatically sets all

 

 

 

 

 

 

(SLV) control

 

 

 

 

 

 

 

the parameters related to SLV. If you config-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ure the inverter to use SLV, we highly recommend letting the auto-tuning procedure derive the values for you. If you want to reset the parameters to the factory default settings, use the procedure in “Restoring Factory Default Settings” on page 6–8.

NOTE: The auto-tuning procedure and related warning messages are in “Auto-tuning for Sensorless Vector Control” on page 4–35. Please read these before trying to auto- tune the motor parameters.

 

 

 

 

 

 

 

 

 

 

Configuring ParametersDrive

 

 

AUX AUTO

NOR

00... Auto-tuning OFF

 

 

Defaults

 

 

 

 

“H” Function

Run

 

 

 

 

Func.

Name /

Description

Mode

–FE

–FU

–FR

Units

 

 

Code

SRW Display

 

 

(CE)

(UL)

(Jpn)

 

 

 

 

 

 

 

 

 

 

 

 

 

H_01

Auto-tuning Setting

Three states for auto-tuning

00

00

00

 

 

 

 

 

function, option codes:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01... Auto-tune (rotate motor)

 

 

 

 

 

 

 

 

 

 

02... Auto-tune (measure motor

 

 

 

 

 

 

 

 

 

 

resistance and inductance,

 

 

 

 

 

 

 

 

 

 

without rotating)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H_02

Motor data selection

Two selections, option codes:

00

00

00

 

 

 

 

 

00... Use standard motor data

 

 

 

 

 

 

 

 

AUX DATA

NOR

 

 

 

 

 

 

 

 

01... Use auto-tuning data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H202

Motor data selection,

Two selections, option codes:

00

00

00

 

 

 

2nd motor

 

00... Use standard motor data

 

 

 

 

 

 

 

 

 

 

01... Use auto-tuning data

 

 

 

 

 

 

 

 

2AUXDATA

NOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H_03

Motor capacity

Nine selections:

Specified by the

kW

 

 

 

 

 

0.2 / 0.4 / 0.75 / 1.5 / 2.2 / 3.7

 

capacity of each

 

 

 

 

AUX K

0.4 kW

 

 

 

 

 

5.5 / 7.5 / 11

 

inverter model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H203

Motor capacity, 2nd

Nine selections:

Specified by the

 

 

 

setting

 

0.2 / 0.4 / 0.75 / 1.5 / 2.2 / 3.7

 

capacity of each

 

 

 

 

 

 

5.5 / 7.5 / 11

 

inverter model

 

 

 

 

2AUXK

0.4 kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H_04

Motor poles setting

Four selections:

4

4

4

poles

 

 

 

 

 

2 / 4 / 6 / 8

 

 

 

 

 

 

 

 

AUX P

4p