B–6

Parameter Settings for Keypad Entry

Fine Tuning Functions

 

 

 

“B” Group Parameters

Default Setting

User

 

 

 

 

 

 

 

 

 

 

 

Func.

 

-FE

-FU

–FR

 

 

 

Name

Setting

 

 

 

Code

(Europe)

(USA)

(Japan)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B_01

Selection of automatic restart

00

00

00

 

 

 

 

 

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B_02

Allowable under-voltage power

1.0

1.0

1.0

 

 

 

 

 

failure time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B_03

Retry wait time before motor

1.0

1.0

1.0

 

 

B

 

 

restart

 

 

 

 

 

 

 

 

 

 

 

 

 

Appendix

 

B_12

Level of electronic thermal

Rated

Rated

Rated

 

 

 

 

setting

current for

current for

current for

 

 

 

 

 

 

 

 

 

 

 

each

each

each

 

 

 

 

 

 

inverter

inverter

inverter

 

 

 

 

 

 

 

 

 

 

 

 

 

B212

Level of electronic thermal

Rated

Rated

Rated

 

 

 

 

 

setting, 2nd motor

current for

current for

current for

 

 

 

 

 

 

each

each

each

 

 

 

 

 

 

inverter

inverter

inverter

 

 

 

 

 

 

 

 

 

 

 

 

 

B_13

Electronic thermal characteristic

01

01

00

 

 

 

 

 

 

 

 

 

 

 

 

 

B213

Electronic thermal characteristic,

01

01

00

 

 

 

 

 

2nd motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B_21

Overload restriction operation

01

01

01

 

 

 

 

 

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B_22

Overload restriction setting

Rated

Rated

Rated

 

 

 

 

 

 

current x

current x

current x

 

 

 

 

 

 

1.25

1.25

1.25

 

 

 

 

 

 

 

 

 

 

 

 

 

B_23

Deceleration rate at overload

1.0

1.0

1.0

 

 

 

 

 

restriction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B_31

Software lock mode selection

01

01

01

 

 

 

 

 

 

 

 

 

 

 

 

 

B_81

[FM] terminal analog meter

80

80

80

 

 

 

 

 

adjustment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B_82

Start frequency adjustment

0.5

0.5

0.5

 

 

 

 

 

 

 

 

 

 

 

 

 

B_83

Carrier frequency setting

5.0

5.0

12.0

 

 

 

 

 

 

 

 

 

 

 

 

 

B_84

Initialization mode (parameters

00

00

00

 

 

 

 

 

or trip history)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B_85

Country code for initialization

01

02

00

 

 

 

 

 

 

 

 

 

 

 

 

 

B_86

Frequency scaling conversion

1.0

1.0

1.0

 

 

 

 

 

factor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B_87

STOP key enable

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

B_88

Restart mode after FRS

00

00

00