Main
Possible with SJ700 Series
High performance, powerful functions, yet user friendly.
For More Precise Control For General Purpose Use
*
700 S
700B
Possible with SJ700 Series
High performance, powerful functions, yet user friendly.
1 2
700 S
700B
Ease of Maintenance Easy Operation
Conformity to global standards
Basic mode (default)
Other Functions
Environmental Friendliness
Ease of Maintenance Easy Operation
Conformity to global standards
Basic mode (default)
Other Functions
Environmental Friendliness
SJ700 Series
SJ700B Series
SJ700 series
SJ700
SJ700B
SJ700 Series
SJ700B Series
SJ700 series
SJ700
SJ700B
SPECIFICATIONS
General Specifications
SJ700-004037 LFUF2, LFF2 SJ700-007040HFEF2, HFUF2, 007037HFF2
SJ700-150220 LFUF2,LFF2 /HFEF2, HFUF2,HFF2 SJ700B-185300HFF
SJ700-550 LFUF2,LFF2
SPECIFICATIONS
General Specifications
* 1850H,2200H,3150H and 4000H of US/JP Version:Please contact Hitachi sales office.
SJ700-750, HFEF2, HFUF2, HFF2 SJ700B-, 1100HFF
SJ700-1100HFF2 SJ700B-1320
SJ700-1850,2200HFE2
SJ700-3150HFE2
SJ700-4000HFE2
SJ700-750, HFEF2, HFUF2, HFF2 SJ700B-, 1100HFF
SJ700-1100HFF2 SJ700B-1320
SJ700-1850,2200HFE2
SJ700-3150HFE2
SJ700-4000HFE2
FUNCTION LIST
OPERATION and PROGRAMMING
Display Unit LEDs
The contents of a basic mode display.(default)
3appears.
FUNCTION LIST OPERATION and PROGRAMMING
MONITORING FUNCTIONS and MAIN PROFILE PARAMETERS
Display Unit LEDs
The contents of a basic mode display.(default)
3appears.
B GROUP: FINE TUNING FUNCTIONS
(*1) 4000HF:5.0 (*2) 4000HF:0.00 to 99.99,100.0 to 120.0 (Hz) (*3) 4000HF:0. to 120.(Hz)
External frequency adjustment
Operation-target frequency
V/f CharacteristicDC BrakingPID ControlAVR
B GROUP: FINE TUNING FUNCTIONS
(*1) 4000HF:5.0 (*2) 4000HF:0.00 to 99.99,100.0 to 120.0 (Hz) (*3) 4000HF:0. to 120.(Hz)
External frequency adjustment
Operation-target frequency
V/f CharacteristicDC BrakingPID ControlAVR
Window comparator
Torque limitation
Intelligent output terminalsAnalog monitoring
(*1) 4000HF: 0.0 to 120.0(Hz) (*2)4000HF: 0.00 to 99.99, 100.0 to 120.0(Hz)
Window comparator
Torque limitation
Intelligent output terminalsAnalog monitoring
(*1) 4000HF: 0.0 to 120.0(Hz) (*2)4000HF: 0.00 to 99.99, 100.0 to 120.0(Hz)
Meter adjustment
H GROUP: MOTOR CONSTANTS FUNCTIONS
Meter adjustment
Levels and output terminal status Communication function Adjustment Others
Adjustment
Input terminal response
OPERATOR
U GROUP: USER-SELECTABLE MENU FUNCTIONS
Absolute position control
*
P GROUP: EXPANSION CARD FUNCTIONS
OPERATOR
U GROUP: USER-SELECTABLE MENU FUNCTIONS
Absolute position control
*
P GROUP: EXPANSION CARD FUNCTIONS
Main Circuit Terminals
Screw Diameter and Terminal Width
7
L300PTM is available in case a relay output function is nessessary.
R0T0
Main Circuit Terminals
Screw Diameter and Terminal Width
7
L300PTM is available in case a relay output function is nessessary.
R0T0
PROTECTIVE FUNCTIONS
Source type logic
IM
How to access the details about the present fault
)
PROTECTIVE FUNCTIONS
Source type logic
IM
How to access the details about the present fault
P24
CONNECTING TO PLC
Connection with Input Terminals
Connection with Output Terminals
1.Using Internal Power Supply of The Inverter
2.Using External Power Supply
CONNECTING TO PLC
Connection with Input Terminals
Connection with Output Terminals
1.Using Internal Power Supply of The Inverter
2.Using External Power Supply
WIRING and ACCESSORIES
Fuse
SJ700B Series / Maximum Torque with Short - Time Rating
400V
Inverter
WIRING and ACCESSORIES
Fuse
SJ700B Series / Maximum Torque with Short - Time Rating
400V
Inverter
DIFFERENCE and COMPATIBILITY of SJ300 series and SJ700 series
SJ700/SJ700B Series / Torque Under Continous Operation
DERATING DATA
90kW 30kW
11 18.5kW
DIFFERENCE and COMPATIBILITY of SJ300 series and SJ700 series
DERATING DATA
90kW 30kW
11 18.5kW
160kW
DIFFERENCE and COMPATIBILITY of L300P series and SJ700B series MEMO
L300P
DIFFERENCE and COMPATIBILITY of L300P series and SJ700B series
MEMO
L300P
FOR CORRECT OPERATION
Application to Motors
Application to general-purpose motors
Application to special motors
Application to the 400V-class motor
Main power supply
Notes on Peripheral Equipment Selection
High-frequency Noise and Leakage Current
Lifetime of Primary Parts
Precaution for Correct Usage