FUNCTION LIST

MONITORING FUNCTIONS and MAIN PROFILE PARAMETERS

Code

Function Name

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Monitored data or setting

 

d001

Output frequency monitor

 

0.00 to 99.99, 100.0 to 400.0 (Hz) (*1)

 

 

 

d002

Output current monitor

 

0.0 to 999.9, 1000 to 9999 (A)

 

d003

Rotation direction minitoring

 

F (forward rotation), o (stopped), r (reverse rotation)

 

d004

Process variable (PV), PID feedback monitor

 

0.00 to 99.99, 100.0 to 999.9, 1000. to 9999. 1000 to 9999 (10000 to 99990),100 to999 (10000 to 999000)

 

 

 

 

 

FW

 

 

 

 

 

 

 

 

 

 

 

ON

(Example) FW, 7, 2, 1 : ON

 

d005

Intelligent input terminal status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8, 6, 5, 4, 3 : OFF

 

 

 

 

8

7

6

5

4

3

2

1

 

 

d006

Intelligent output terminal status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

(Example) 12, 11 : ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

AL, 15, 14, 13 :OFF

 

 

 

 

 

 

 

AL 15

1413

12 11

 

 

 

 

 

 

 

 

 

d007

Scaled output frequency monitoring

 

0.00 to 99.99, 100.0 to 999.9, 1000. to 9999., 1000 to 3996 (10000 to 39960)

 

d008

Actual-frequency monitoring

 

-400. to -100., -99.9 to 0.00 to 99.99, 100.0 to 400.0 (Hz) (*2)

 

d009

Torque command monitoring

 

0. to +200. (%)

 

 

 

 

 

 

 

d010

Torque bias monitoring

 

-200. to +200. (%)

 

 

 

 

 

d012

Torque monitoring

 

-200. to +200. (%)

 

 

 

 

 

d013

Output voltage monitoring

 

0.0 to 600.0 (V)

 

 

 

 

 

 

 

d014

Power monitoring

 

0.0 to 999.9 (kW)

 

 

 

 

Mode

d015

Cumulative power monitoring

 

0.0 to 999.9, 1000. to 9999.,1000 to 9999 (10000 to 99990),100 to999 (100000 to 999000)

d016

Cumulative operation RUN time monitoring

 

0. to 9999., 1000 to 9999 (10000 to 99990),100 to999 (10000 to 999000) (hr)

 

 

Monitor

d017

Cumulative power-on time monitoring

 

0. to 9999., 1000 to 9999 (10000 to 99990),100 to999 (10000 to 999000) (hr)

d018

Heat sink temperature monitoring

 

-020. to 200.0 ()

 

 

 

 

 

d019

Motor temperature monitoring

 

-020. to 200.0 ()

 

 

 

 

 

d022

Life-check monitoring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

1: Capacitor on main circuit board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

2: Cooling-fan speed drop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

d023

Program counter

 

0 to 1024

 

 

 

 

 

 

 

 

 

 

d024

Program number monitoring

 

0000 to 9999

 

 

 

 

 

 

 

 

 

d025

User monitor 0

 

-2147483647 to 2147483647 (upper 4 digits including “-“)

 

d026

User monitor 1

 

-2147483647 to 2147483647 (upper 4 digits including “-“)

 

d027

User monitor 2

 

-2147483647 to 2147483647 (upper 4 digits including “-“)

 

d028

Pulse counter

 

0 to 2147483647 (upper 4 digits)

 

d029

Position setting monitor

 

-1073741823 to 1073741823 (upper 4 digits including “-“)

 

d030

Position feedback monitor

 

-1073741823 to 1073741823 (upper 4 digits including “-“)

 

d080

Trip Counter

 

0. to 9999., 1000 to 6553 (10000 to 65530) (times)

 

d081

Trip monitoring 1-6

 

Factor, frequency (Hz), current (A), voltage across P-N (V),

 

-

 

running time (hours), power-on time (hours)

 

d086

 

 

 

d090

Programming error monitoring

 

Warning code

 

 

 

 

 

 

 

 

 

d102

DC voltage monitoring

 

0.0 to 999.9 (V)

 

 

 

 

 

 

 

d103

BRD load factor monitoring

 

0.0 to 100.0 (%)

 

 

 

 

 

 

 

d104

Electronic thermal overload monitoring

 

0.0 to 100.0 (%)

 

 

 

 

 

 

 

F001

Output frequency setting

 

0.0, "start frequency" to "maximum frequency" (or maximum frequency, 2nd/3rd motors) (Hz)

Mode

 

0.0 to 100.0 (when PID function is enabled)

F002

Acceleration (1) time setting

 

 

0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)

F202

Acceleration (1) time setting, 2nd motor

 

0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)

Setting

F302

Acceleration (1) time setting, 3rd motor

 

0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)

F203

Deceleration time setting, 2nd motor

 

0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)

 

F003

Deceleration (1) time setting

 

0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)

 

F303

Deceleration time setting, 3rd motor

 

0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)

Function

F004

Keypad Run key routing

 

00 (forward rotation), 01 (reverse rotation)

A---

A Group: Standard functions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b---

b Group: Fine tuning functions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Expanded

C---

C Group: Intelligent terminal functions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U---

U Group: User-selectable menu functions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H---

H Group: Motor constants functions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P---

P Group: Expansion card functions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(*1) 4000HF:0.00 to 99.99,100.0 to 120.0(Hz) (*2)4000HF: -120. to -100., -99.9 to 0.00 to 99.99,100.0 to 120.0(Hz)

A GROUP: STANDARD FUNCTIONS

 

 

 

[◯= Allowed×= Not permitted

 

 

 

 

 

 

Default Setting

 

Setting

Change

 

 

SJ700

 

SJ700B

during operation during operation

-FE(CE) -FU(UL)

-F(JP)

(allowed or not)

(allowed or not)

-

 

-

-

-

 

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

*)

-

 

 

-

 

-

-

-

-

-

 

 

-

 

-

-

-

*)

-

-

 

 

-

 

-

-

-

*)

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

*)

-

-

 

 

-

 

-

-

-

-

-

 

 

-

 

-

-

-

*)

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

-

 

-

-

-

 

-

-

 

 

0.00

 

0.00

0.00

0.00

30.00

 

30.00

30.00

30.00

30.00

 

30.00

30.00

30.00

30.00

 

30.00

30.00

30.00

30.00

 

30.00

30.00

30.00

30.00

 

30.00

30.00

30.00

30.00

 

30.00

30.00

30.00

00

 

00

00

00

 

×

×

 

 

*) Not available

[◯= Allowed×= Not permitted

Default Setting

Setting

Change

Code

settings

A001

A003

 

A002

Basic

A203

A303

 

 

A004

 

A204

 

A304

input

A005

othersand

A006

Analog

Function Name

 

Monitored data or setting

Frequency source setting

 

(keypad potentiometer) (*1), 01 (control circuit terminal block),

00

02

(digital operator), 03 (RS485), 04 (option 1), 05 (option 2),

 

06

(pulse-string input), 07 (easy sequence), 10 (operation function result)

Run command source setting

01 (control circuit terminal block), 02 (digital operator), 03 (RS485), 04 (option 1), 05 (option 2)

Base frequency setting

30. to "maximum frequency " (Hz)

Base frequency setting, 2nd motor

30. to "maximum frequency, 2nd motor" (Hz)

Base frequency setting, 3rd motor

30. to "maximum frequency, 3rd motor" (Hz)

Maximum frequency setting

30. to 400. (Hz) (*2)

Maximum frequency setting, 2nd motor

30. to 400. (Hz) (*2)

Maximum frequency setting, 3rd motor

30. to 400. (Hz) (*2)

[AT] selection

00 (switching between O and OI terminals), 01 (switching between O and O2 terminals),

02 (switching between O terminal and keypad potentiometer) (*1), 03 (switching between OI terminal

 

and keypad potentiometer) (*1), 04 (switching between O2 and keypad potentiometer) (*1)

[O2] selection

00

(single), 01 (auxiliary frequency input via O and OI terminals) (nonreversible),

02 (auxiliary frequency input via O and OI terminals) (reversible), 03 (disabling O2 terminal)

 

 

SJ700

 

 

during operation during operation

 

 

SJ700B (allowed or not)

(allowed or not)

-FE(CE) -FU(UL)

-F(JP)

01

01

02

01

×

×

01

01

02

01

×

×

50.

60.

60.

50.

×

×

50.

60.

60.

50.

×

×

50.

60.

60.

50.

×

×

50.

60.

60.

50.

×

×

50.

60.

60.

50.

×

×

50.

60.

60.

50.

×

×

00

00

00

00

×

×

03

03

03

03

×

×

 

 

 

 

 

 

(*1) This setting is valid only when the OPE-SR is connected. (*2) 4000HF:30. to 120. (Hz)

12

Page 13
Image 13
Hitachi SJ700B manual Function List

SJ700B, SJ700 specifications

The Hitachi SJ700 and SJ700B series are renowned variable frequency drives (VFDs) that represent a significant advancement in motor control technology. Designed for industrial applications, these drives offer a versatile solution for managing motor speed, torque, and efficiency in a variety of settings.

One of the main features of the SJ700 and SJ700B series is their compact design. This allows for easy installation and integration into existing systems, which is crucial for minimizing downtime during upgrades or replacements. The drives support multiple mounting orientations, facilitating applications with space constraints.

Another standout characteristic is their advanced control algorithms. The SJ700 series uses vector control technology, which optimizes the performance of both AC and induction motors. This ensures high precision in speed and torque control, making it suitable for processes that require fine adjustments. The drives also feature automatic tuning capabilities, which allow for quick commissioning while minimizing the need for extensive parameter adjustments.

The SJ700 and SJ700B series are designed with energy efficiency in mind. They utilize advanced regenerative braking technology that recovers energy, reducing power consumption and improving overall system efficiency. Furthermore, these drives incorporate energy-saving features that optimize motor operation based on load requirements, contributing to a lower carbon footprint.

These drives come equipped with robust communication capabilities. They support various communication protocols such as Modbus, Profibus, and EtherCAT, making them easily integrable with modern automation systems. This flexibility allows for real-time monitoring and control, enhancing operational visibility and efficiency.

Reliability is another hallmark of the SJ700 series. Built with high-quality components, these drives exhibit excellent thermal management and protection against overvoltage, overload, and short circuits. The SJ700B variant boasts additional features such as enhanced fault diagnostics and improved environmental protection, making it suitable for more demanding applications.

In conclusion, the Hitachi SJ700 and SJ700B series variable frequency drives stand out in terms of compact design, advanced control technologies, energy efficiency, versatile communication options, and robust reliability. These features make them an ideal choice for a wide range of industrial applications, from manufacturing automation to HVAC systems, ensuring optimal performance and cost savings for users.