4-6. Connecting to Weld Output Terminals

1 Negative (–) Weld Output

Terminal

2 Positive (+) Weld Output

Terminal

For Direct Current Electrode Positive (DCEP), connect work cable to Negative (–) terminal and electrode holder to Positive (+) terminal.

For Direct Current Electrode negative (DCEN), reverse cable connections.

1

2

Tools Needed:

3/4 in

Ref. ST-192 519-A / Ref. ST-802 210-B

4-7. Selecting Weld Cable Sizes

 

 

 

Total Cable (Copper) Length In Weld Circuit Not Exceeding

 

 

 

 

 

 

 

 

 

 

 

 

Welding

100 ft (30 m) Or Less

 

150 ft

200 ft

250 ft

300 ft

350 ft

400 ft

 

(45 m)

(60 m)

(70 m)

(90 m)

(105 m)

(120 m)

Amperes

 

 

 

 

 

 

 

 

 

 

 

 

 

10 – 60%

60 – 100% Duty

 

 

10 – 100% Duty Cycle

 

 

 

Duty Cycle

Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

4

4

 

4

3

2

1

1/0

1/0

 

 

 

 

 

 

 

 

 

 

150

3

3

 

2

1

1/0

2/0

3/0

3/0

 

 

 

 

 

 

 

 

 

 

200

3

2

 

1

1/0

2/0

3/0

4/0

4/0

 

 

 

 

 

 

 

 

 

 

250

2

1

 

1/0

2/0

3/0

4/0

2-2/0

2-2/0

 

 

 

 

 

 

 

 

 

 

300

1

1/0

 

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

 

 

 

 

 

 

 

 

 

 

350

1/0

2/0

 

3/0

4/0

2-2/0

2-3/0

2-3/0

2-4/0

 

 

 

 

 

 

 

 

 

 

400

1/0

2/0

 

3/0

4/0

2-2/0

2-3/0

2-4/0

2-4/0

 

 

 

 

 

 

 

 

 

 

500

2/0

3/0

 

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-3/0

 

 

 

 

 

 

 

 

 

 

*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. Contact your

distributor for the mm2 equivalent weld cable sizes.

S-0007-E

OM-493 Page 16

Page 20