Step 1. Scan the 1st Left Identifier bar code, below.

Step 2. Use the Programming Chart to scan 3, D (hex for “=”). Step 3. Scan Save.

Step 4. Scan the 2nd Left Identifier bar code, below.

Step 5. Use the Programming Chart to scan 4, 7 (hex for “G”). Step 6. Scan Save.

Step 7. Scan the 1st Right Identifier bar code, below.

Step 8. Use the Programming Chart to scan 3, D (hex for “=”). Step 9. Scan Save.

Step 10. Scan the 2nd Right Identifier bar code, below.

Step 11. Use the Programming Chart to scan 3, C (hex for “<”). Step 12. Scan Save.

Once you have programmed the concatenation sequence, use ISBT 128 User-Defined Concatenation Sequences to enable this feature. Default =

0.

1st Left Identifier2nd Left Identifier1st Right Identifier2nd Right IdentifierISBT 128 User-Defined Concatenation Sequences On/Off

The following selections allow you to enable or require the User-Defined ISBT 128 Concatenation Sequences.

If you scan Off, the User-Defined concatenation sequences are disabled.

If you scan the Allow User-Defined Sequence code, then the scanner will output only the data combination specified in the User-Defined concatenation sequence you created.

6 - 27