Insert a delay
EF Inserts a delay of up to 49,995 milliseconds (in multiples of 5), starting from the current cursor position. Syntax = EFnnnn where nnnn stands for the delay in 5ms increments, up to 9999. This command can only be used with keyboard emulation.
Data Formatter
When Data Formatter is turned Off, the bar code data is output to the host as read, including prefixes and suffixes.
Data Formatter Off
You may wish to require the data to conform to a data format you have created and saved. The following settings can be applied to your data format:
Data Formatter On, Not Required, Keep Prefix/SuffixScanned data is modified according to your data format, and prefixes and suffixes are transmitted.
Data Format Required, Keep Prefix/SuffixScanned data is modified according to your data format, and prefixes and suffixes are transmitted. Any data that does not match your data format requirements generates an error tone and the data in that bar code is not transmitted.
Default = Data Formatter On, Not Required, Keep Prefix/Suffix.
*Data Formatter On, Not Required,
Keep Prefix/Suffix
Data Format Required,
Keep Prefix/Suffix
Primary/Alternate Data Formats
You can save up to four data formats, and switch between these formats. Your primary data format is saved under 0. Your other
three formats are saved under 1, 2, and 3. To set your device to use one of these formats, scan one of the bar codes below.
Primary Data Format
Data Format 1
Data Format 2
6 - 9