Selection | Setting | Serial Command | Page | |
* Indicates default | # Indicates a numeric entry | |||
|
| |||
|
|
|
| |
|
|
|
| |
Cordless System Operation |
|
|
| |
Note: This section applies only to cordless systems. It does not apply to corded scanners. |
| |||
Base Power Communication | *On | :*:BASRED1 | ||
Indicator |
|
|
| |
Off | :*:BASRED0 | |||
| ||||
|
|
|
| |
Reset Scanner | Reset Scanner | RESET_ | ||
|
|
|
| |
Scanning While in Base Cradle | Scanning in Cradle Off | BT_SIC0 | ||
|
|
|
| |
| *Scanning in Cradle On | BT_SIC1 | ||
|
|
|
| |
| Shut Down Scanner in Cradle | BT_SIC2 | ||
|
|
|
| |
Base Charging Modes | Base Charge Off | BASCHG0 | ||
|
|
|
| |
| *External or Interface Cable Power | BASCHG1 | ||
|
|
|
| |
| External Power Only | BASCHG2 | ||
|
|
|
| |
Paging Mode | *On | BEPPGE1 | ||
|
|
|
| |
| Off | BEPPGE0 | ||
|
|
|
| |
Paging Pitch | Low (*1000 Hz) | BEPPFQ1000 | ||
|
|
|
| |
| Medium (3250 Hz) | BEPPFQ3250 | ||
|
|
|
| |
| High (4200) | BEPPFQ4200 | ||
|
|
|
| |
Beeper Pitch - Base Error | *Razz (250) (min 200Hz) | BASFQ2250 | ||
|
|
|
| |
| Medium (3250) | BASFQ23250 | ||
|
|
|
| |
| High (4200) (max 9000Hz) | BASFQ24200 | ||
|
|
|
| |
Number of Beeps - Base Error | *1 | BASERR3 | ||
|
|
|
| |
| Range 1 - 9 | BASERR# | ||
|
|
|
| |
Scanner Report | Scanner Report | RPTSCN | ||
|
|
|
| |
Scanner Address | Scanner Address | BT_LDA | ||
|
|
|
| |
Base Address | Base Address | :*:BASLDA | ||
|
|
|
| |
Scanner Modes | Charge Only Mode | :*:BASLNK0 | ||
|
|
|
| |
| *Charge and Link Mode | :*:BASLNK1 | ||
|
|
|
| |
| Locked Link Mode | BASCON0,DNG1 | ||
|
|
|
| |
| *Open Link Mode | BASCON1,DNG1 | ||
|
|
|
| |
| Unlink Scanner | BT_RMV | ||
|
|
|
| |
| Override Locked Scanner | BT_RPL1 | ||
|
|
|
| |
Base Alarm Duration (Range 1 - 3000 sec | BASORD | |||
| (*0)) |
|
| |
|
|
|
| |
| Scanner Alarm Duration (Range 1 - 3000 | BT_ORD | ||
| sec (*0)) |
|
| |
|
|
|
| |
Alarm Sound Type | Base Alarm Type | BASORW | ||
|
|
|
| |
| Scanner Alarm Type | BT_ORW | ||
|
|
|
| |
Scanner Power | Timer | BT_LPT0 | ||
|
|
|
| |
| 200 Seconds | BT_LPT200 | ||
|
|
|
| |
| 400 Seconds | BT_LPT400 | ||
|
|
|
| |
| 900 Seconds | BT_LPT900 | ||
|
|
|
| |
| 3600 Seconds | BT_LPT3600 | ||
|
|
|
| |
| 7200 Seconds | BT_LPT7200 | ||
|
|
|
|
10 - 8