FF termination string for third code

To program the previous example using specific lengths, you would have to count any programmed prefixes, suffixes, or formatted characters as part of the length. If you use the example on page 4-20, but assume a <CR> suffix and specific code lengths, you would use the following command line:

SEQBLK62001241FF6A001342FF69001243FF

The breakdown of the command line is shown below:

SEQBLKsequence editor start command

62 code identifier for Code 39

0012 A - Code 39 sample length (11) plus CR suffix (1) = 12

41start character match for Code 39, 41h = “A”

FF termination string for first code

6A code identifier for Code 128

0013 B - Code 128 sample length (12) plus CR suffix (1) = 13

42start character match for Code 128, 42h = “B”

FF termination string for second code

69code identifier for Code 93

0012 C - Code 93 sample length (11) plus CR suffix (1) = 12

43start character match for Code 93, 43h = “C”

FF termination string for third code

Output Sequence Editor

Enter Sequence

Default Sequence

Partial Sequence

If an output sequence operation is terminated before all your output sequence criteria are met, the bar code data acquired to that point is a “partial sequence.”

4 - 21