W - Target White Value
Sets the target for the median grayscale value in the captured image. For capturing
nW Range: 0 - 255
Example of White | Example of White | Example of White |
Value at 75W: | Value at 125W: | Value at 200W: |
D - Delta for Acceptance
This sets the allowable range for the white value setting (see W - Target White Value). Delta is only available when using Photo Style (1P). (Default = 25)
nD Range: 0 - 255
U - Update Tries
This sets the maximum number of frames the scanner should take to reach the D - Delta for Acceptance. Update Tries is only available when using Photo Style (1P). (Default = 6)
nU Range: 0 - 10
% - Target Set Point Percentage
Sets the target point for the light and dark values in the captured image. A setting of 75% means 75% of the pixels are at or below the target white value, and 25% of the pixels are above the target white value. Altering this setting from the default is not recommended under normal circumstances. To alter grayscale values, W - Target White Value should be used. (Default = 50)
n% Range: 1 - 99 |
|
|
Example of Target | Example of Target | Example of Target |
Set Point | Set Point | Set Point |
Percentage at 97%: | Percentage at 50%: | Percentage at 40%: |
8 - 4