Note: Replace only with battery pack model 99EX-BTSC (PN 99EX-BTSC-2) or 99EX-BTEC (PN 99EX-BTEC-2) manufactured for Honeywell International Inc.

The standard or extended battery pack is the primary power source for the terminal. The Li-poly and Li- ion battery packs are designed to operate in a temperature range of -10° to 50°C (14° to 122°F).

!CAUTION - Read the Guidelines for Battery Pack Use and Disposal on page 3-14 and all cautionary markings on the battery, charging peripheral, or device using the battery before attempting to install, use, or charge the battery. Risk of fire and burns if improperly handled. Do not open, crush, heat above 60°C (140°F), or incinerate.

Charging Options

When the main battery pack is installed in the terminal, use one of the following peripherals:

Dolphin 99EX HomeBase Device (Model 99EX-HB)(see page 12-1)

Dolphin 99EX eBase Device (Model 99EX-EHB)(see page 13-1)

Dolphin 99EX Mobile Base Device (Model 99EX-MB)(see page 14-1)

Dolphin 99EX ChargeBase Device (Model 99EX-CB)(see page 15-1)

Dolphin 99EX Net Base Device (Model 99EX-NB)(see page 16-1)

When the main battery pack is not installed in the terminal:

Place the battery pack in the Dolphin 99EX QuadCharger Device (Model 99EX-QC)(see page 17-1)

Place the battery pack in the Auxiliary Battery Well of the Dolphin 99EX HomeBase Device (Model 99EX-HB)(see page 12-3)or Dolphin 99EX eBase Device (Model 99EX-EHB)(see page 13-1).

For information on how to remove the main battery pack from the terminal, see Replacing the Main Battery Pack on page 2-6.

Note: The communications/charging circuits connected to the equipment provide the transient protection set at a level not exceeding 140% of the peak rated voltage value of the IO terminal.

Charging Time

The standard 3.7V Li-poly battery pack requires 4 hours to charge completely before initial use. The extended 3.7V Li-ion battery pack requires 6 hours to charge completely before initial use. Honeywell recommends charging the Dolphin terminal for at least 24 hours prior to initial use to ensure the internal backup battery is fully charged.

Battery Error Notification

If your terminal displays the following indicators, replace the main battery pack with a new Honeywell battery pack. For information on how to remove the main battery pack from the terminal, see Replacing the Main Battery Pack on page 2-6.

appears in the Title bar at the top of the touch screen.

The General Notification LED flashes red.

A Notification appears on the Tile bar at the bottom of the touch screen.

Storing Batteries

To maintain top performance from batteries, avoid storing batteries outside of the following temperature ranges:

14°F to 113°F (-10°C to +45°C) for short term storage of less than one month

32°F to 86°F (-0°C to +30°C) for long term storage

3 - 12