the lugs on the exhaust nozzle connector are engaged with the grooves on the connector of unit (Fig. 2).

3.Attach the exhaust nozzle (9) to the exhaust nozzle connector (10).

4.Extend the exhaust hose (11) and close the window as far as possible trapping the exhaust nozzle (9)

INSTALLATION INSTRUCTIONS

Air Conditioning with Installation

If required your appliance can also be installed semi-permanently (Fig. 5).

Proceed as follows:

1.Drill a hole in an outside wall, through a door or a window pane. The hole should be no larger than 125mm, and between 35cm and 100cm from floor level. If you drill through a wall, we recommend that you insulate that section with suitable materials. (Figs. 6-7)

2.Fit the flange accessory fixture (12) provided into the hole.

3.Fit the exhaust hose in the housing at the back of the appliance (Fig. 2).

4.Insert the other end of the exhaust hose to the flange already placed in the hole (Fig. 7).

NOTE: When installing the air conditioner semi-permanently, you should leave a door slightly open (as little as 1cm) to guarantee sufficient ventilation.

OPEREATING INSTRUCTIONS: CONTROL PANEL

Power Control

The power control turns the unit on and off.

Warning Light

Condensed water may accumulate in the unit. If the internal tank becomes full, the warning light in the LCD Display will light up and the unit will not operate until the unit has been drained.

Mode Control

The Mode Control has 3 settings: Cool, Dehumidify, and Fan. The settings are adjusted with the Mode Control button. A light will indicate which setting is being used.

1. Cooling Mode

When cool mode is selected, “ Manual backgroundManual background ” will show in the LCD display. During the cooling mode the air is cooled and hot air is exhausted to the outside air through the exhaust tube. Adjust fan speed and temperature to suit your desired comfort level.

Note : The air exchange hoses must vent outside the room when using Cooling Mode.

2. Dehumidify Mode

When dehumidify mode is selected, “Manual background ” will show in the LCD display. Air is dehumidified as it passes through the air conditioner without being in full cooling mode. If the room temperature is >25°C (77°F), fan speed can be adjusted; otherwise, fan speed is set at Medium.

Note : The warm air exchange hoses must vent inside the room when using Dehumidify Mode, not outside as it does when cooling. If the unit is vented outside some cooling will occur.

3. Fan Mode

 

When fan mode is selected, , or

will be shown in the LCD

display. Air is circulated throughout the room with no cooling.

Note: Unit does not need to be vented in Fan Mode. Fan Speed Control

The Fan Speed Control has 3 settings: Manual background High;

Manual background Medium; and Manual background Low.

Time Setting

Auto Shut Off: With machine in running mode, press the timer button. Press “+” or “-” to select number of hours you would like the unit to run before it automatically shuts off.

Auto Turn On: With machine in stand-by mode, press the timer button. Press “+” or “-” to select number of hours before the unit automatically starts running in air conditioning mode.

NOTE: Time is adjustable between 1-24 hours. Temperature Controls

The temperature control buttons are used for adjusting the thermostat.

The default LCD display is the room temperature.

In cooling mode, when “+” or “-” is pressed the set temperature is displayed and may be adjusted. After 15 seconds the display will revert back to showing the room temperature. Temperature is only adjustable in cool mode.

NOTE: By pressing both the “+” and “-” buttons at the same time for more than 3 seconds, the display will toggle between Celsius and Fahrenheit.

OPERATING INSTRUCTIONS: REMOTE Control

The functions work the same a your air conditioner’s control panel. All key functions can be accessed from the remote control (Fig. 10).

Power Control: On/Off

Fan Speed Control: Manual background High; Manual background Medium; Manual background Low

On/Off Timer Control:

In running mode: Auto switch off

In stand-by mode: Auto switch off

Press “Manual background” or “Manual background” button to adjust the time setting in 1 hour intervals.

Fahrenheit/Celsius Button: toggles between Celsius and Fahrenheit settings.

LCD Display

Time/Temperature Set Control:

Used for adjusting the timer and temperature.

The default display on the control panel is room temperature

When “Manual background” or “Manual background” button is pressed in cool mode the set temperature is displayed and may be adjusted. After 15 seconds the display will revert back to room temperature.

Timer setting is available from 1-24 hours by pressing the “Manual background” or “Manual background”button.” button.

Mode Control: Press to change the operating mode, which will rotate through Cool - Dehumidify - Fan and back to Cool.