PRESSURE SENSORS

TLD Series

With space at a premium in semiconductor gas distribution systems, the Series TLD pressure transducer with local display offers an integrated solution that reduces the overall height of the transducer/display assembly to as little as 3.5 in [88,9 mm]. To accomplish this, the transducer’s signal amplifier is mounted within the display, with the added benefit of zero and span adjustments conveniently located on the LED display face.

Supply voltage:

12.0 Vdc to 30.0 Vdc

Signal conditioning:

Amplified compensated

Operating temperature range:

-40 °C to 85 °C (-40

°F to 185 °F)

Compensated temperature range:

0 °C to 70 °C (32

°F to 158 °F)

Termination type:

1,83 m (6 ft) 2-conductor cable

OPTIONS

Flow-through/Output Signal 4 mA to 20 mA

MEASUREMENT TYPE

PRESSURE RANGE

CONNECTIONS

REFERENCE

Compound

-14.7 psig to 100 psig

1/4 in. OD 0.035 in. wall, 1/4 in long tube stub

TLDF4CVT4V100CP

Compound

-14.7 psig to 100 psig

1/4 in. female face seal, swivel

TLDF4CVVFV100CP

Compound

-14.7 psig to 100 psig

1/4 in. female face seal, swivel

TLDF4BSVFV100CP

Flow-through/Output Signal 0 Vdc to 5.0 Vdc

MEASUREMENT TYPE

PRESSURE RANGE

CONNECTIONS

REFERENCE

Compound

-14.7 psig to 100 psig

1/4 in. OD 0.035 in. wall, 1/4 in long tube stub

TLDF5CVT4V100CP

 

 

 

 

Single Port/Output Signal 4 mA to 20 mA

MEASUREMENT TYPE

PRESSURE RANGE

 

REFERENCE

Compound

-14.7 psig to 100 psig

1/4 in. female face seal, swivel

TLDS4BNVFV100CP

Flow-through display orientation and transducer location

35,9

1.42

 

 

38,1

 

 

 

 

26,1

 

 

 

 

 

 

 

 

 

 

 

1.50

 

 

 

 

1.03

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

38,1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.50

 

 

 

 

 

 

 

 

 

 

z

s

 

 

 

72,4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

82,5

2.85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BS - Transducer at bottom, side display orientation

35,9

1.42

 

 

26,1

 

 

38,1

 

1.03

 

1.50

 

 

 

 

 

 

 

 

 

 

38,1

 

 

 

1.50

 

82,5

72,4

z

s

2.85

 

 

3.25

 

 

 

 

38,1

 

1.50

 

z

 

38,1

 

1.50

CABLE

s

 

2 COND

 

1,8 m (6CVft)- Transducer at center back, vertical display orientation

38,1

1.50

 

38,1

 

1.50

z

s

CH - Transducer at center back, horizontal display orientation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CABLE

 

 

42,7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.68

 

 

 

 

 

 

 

 

 

CABLE

2 COND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

77,0

 

 

 

 

 

 

 

 

 

 

 

 

2 COND

1,8 m (6 ft)

3.03

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1,8 m (6 ft)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BF - Transducer at bottom, front display orientation

140

www.honeywell.com/sensing

Page 142
Image 142
Honeywell Switches and Sensors manual TLD Series, Flow-through/Output Signal 4 mA to 20 mA