SAFETY SWITCHES

GSS Series

Hinge Mount Safety

Limit Switch

The Hinge Mount Safety Limit Switch is designed for use on machine access doors as an alternative solution to key operated interlocks and safety limit switches. When the access door is opened, a follower pin (not supplied) slides down the slot in the actuator lever, forcing the actuator lever to rotate and positively open the NC safety circuit to shut off the machine. Closing the access door rotates the actuator lever to the reset position, closing the NC safety contacts.

The Hinge Mount Safety Limit Switch minimizes alignment problems because it may be offset-mounted from the hinge point of the door. The tamper-resistant design and the positive opening contacts provide a higher level of safety than the conventional spring-driven limit switches often used to monitor door position.

Low Energy Switching

In today’s demanding age of low energy controls, electromechanical switches are frequently used to interface directly with safety relays, PLCs and other low energy devices. To accommodate this requirement GSS offers a new gold plated contact version of the standard basic switch. This improves reliability of switching at low currents and voltages by protecting the contact surfaces from contamination during operation or storage prior to use.

Standard silver contacts have a disadvantage in that the contact surface may tarnish under certain environmental conditions, e.g. in the presence of moisture.

Low energy basic switches are rated as follows:

Operating Voltage Ue 1 Vdc to 60 Vdc or 1 Vac to 125 Vac

Operating Current Ie 1 mA to 50 mA

Example of catalog listing using a low energy basic switch - GSCB33S2.

Switching options:

 

 

 

 

GSC/D

 

 

GSE

Snap action contacts (1NC/1NO)

Slow action contacts (4NC)

 

 

11

12

 

13

14

21

22

 

 

 

4Y

21

22 Zb

31

32

41

42

 

 

 

 

Slow action contacts (1NC/1NO) BBM

Slow action contacts (2NC/2NO) BBM

 

 

11

12

 

21

22

21

22

 

 

 

 

 

 

Zb

 

 

2Y, 2X

 

 

 

 

13

14

33

34

 

 

 

 

 

 

 

 

 

 

43

44

 

Slow action contacts (2NC)

Slow action contacts (3NC/1NO) BBM

 

 

11

12

 

11

12

21

22

 

 

2Y

31

32

 

 

 

 

 

21

22

 

3Y, 1X

43

44

 

 

 

 

Electrical ratings:

IEC 60947-5-1/EN 60947-5-1

 

 

 

 

Rated operational current le (A)

 

VA

 

Designation & Utilization

 

 

at rated operational voltage Ue

 

rating

 

 

Category

120 V

240 V

380 V

480 V

500 V

600 V

Make

Break

 

 

AC15

A600

6

3

1,9

1,5

1,4

1,2

7200

720

AC15

A300

6

3

-

-

-

-

7200

720

AC15

B300

3

1.5

-

-

-

-

3600

360

AC14

D300

0,6

0,3

-

-

-

-

432

72

 

 

125 V

250 V

 

 

 

 

 

 

DC13

Q300

0,55

0,27

 

 

 

 

69

69

DC13

R300

0,22

0,1

 

 

 

 

28

28

80

www.honeywell.com/sensing