Honeywell Switches and Sensors manual Ring actuator seal, Field adjustable roller plunger

Models: Switches and Sensors

1 148
Download 148 pages 35.22 Kb
Page 43
Image 43

PRECISION LIMIT SWITCHES

Momentary contact (continued)

Top roller plunger, parallel

Roller arm, adjustable

Right-hand

Left-hand

 

*28,2 on DTF2 Types

 

1.11

O-ring actuator seal

Operating force max. (OF):

BAF/DTF

 

35,6 N (8.0 lb)

Pretravel max. (PT):

 

BAF/DTF

3,18 mm (0.125 in)

Overtravel min. (OT):

 

BAF

 

4,75 mm (0.187 in)

 

 

DTF

 

3,18 mm (0.125 in)

Differential travel max. (DT):

BAF

 

0,19 mm (0.0075 in)

 

 

DTF

 

1,53 mm (0.060 in)

Operating position (OP):

 

BAF

 

64,69 mm (2.547 in)

 

 

DTF

 

63,88 mm (2.515 in)

ACTUATOR POSITION

CONTACT

ELECTRICAL RATING

REFERENCE

Right

SPDT

 

D

BAF1-2RQN8-RH

Left

SPDT

 

D

BAF1-2RQN8-LH

Right

DPDT

 

B

DTF2-2RQN8-RH

Left

DPDT

 

B

DTF2-2RQN8-LH

 

 

 

 

 

Field adjustable roller plunger

Adjustable 360° horizontally

Operating force max. (OF):

BAF/DTF

11,2 N (2.5 lb)

Pretravel max. (PT):

BAF

2,39 mm (0.094 in)

 

DTF

3,18 mm (0.125 in)

Overtravel min. (OT):

BAF

3,96 mm (0.156 in)

 

DTF

3,18 mm (0.125 in)

Differential travel max. (DT):

BAF

0,26 mm (0.010 in)

 

DTF

1,53 mm (0.060 in)

Operating position (OP):

BAF

64,69 mm (2.547 in)

 

DTF

63,88 mm (2.515 in)

ACTUATOR POSITION

CONTACT

ELECTRICAL RATING

REFERENCE

Right

SPDT

D

BAF1-2RQ9-RH

Left

SPDT

D

BAF1-2RQ9-LH

Right

DPDT

B

DTF2-2RQ9-RH

Left

DPDT

B

DTF2-2RQ9-LH

 

 

 

 

With boot seal

Operating force max. (OF):

BAF

8,90 N (2.0 lb)

 

 

DTF

11,1 N (2.5 lb)

Pretravel max. (PT):

 

BAF

5,56 mm (0.219 in)

 

 

DTF

7,93 mm (0.312 in)

Overtravel min. (OT):

 

BAF

6,35 mm (0.25 in)

 

 

DTF

5,56 mm (0.219 in)

Differential travel max. (DT):

BAF

0,51 mm (0.020 in)

 

 

DTF

3,05 mm (0.120 in)

ACTUATOR POSITION

CONTACT

ELECTRICAL RATING

REFERENCE

Right

SPDT

D

BAF1-2RN2-RH

Left

SPDT

D

BAF1-2RN2-LH

Right

DPDT

B

DTF2-2RN2-RH

Right

DPDT

B

DTF2-2RN2-LH

One way roller lever

With boot seal

Operating force max. (OF):

 

8,90 N (2.0 lb)

Pretravel max. (PT):

 

 

5,56 mm (0.219 in)

Overtravel min. (OT):

 

 

6,35 mm (0.25 in)

Differential travel max. (DT):

 

0,51 mm (0.020 in)

ACTUATOR POSITION

CONTACT

ELECTRICAL RATING

REFERENCE

Right

SPDT

D

BAF1-2RN28-RH

Left

SPDT

D

BAF1-2RN28-LH

 

 

 

 

www.honeywell.com/sensing

41

Page 43
Image 43
Honeywell Switches and Sensors manual Ring actuator seal, Field adjustable roller plunger, One way roller lever