Summary of Audible Notification
(Alpha Display Keypads)
SOUND | CAUSE | DISPLAY |
LOUD, | FIRE ALARM | FIRE is displayed; descriptor of zone in alarm is displayed. |
INTERRUPTED* |
|
|
Keypad & External |
|
|
LOUD, | BURGLARY/AUDIBLE | ALARM is displayed; descriptor of zone in alarm is also |
CONTINUOUS* | EMERGENCY ALARM | displayed. |
Keypad & External |
|
|
ONE SHORT BEEP | a. SYSTEM DISARM | a. DISARMED/READY TO ARM is displayed. |
(not repeated) | b. SYSTEM ARMING ATTEMPT | b. The number and descriptor of the open protection zone |
Keypad only | WITH AN OPEN ZONE. | is displayed. |
| c. BYPASS VERIFY | c. Numbers and descriptors of the bypassed protection |
|
| zones are displayed (One beep is heard for each zone |
|
| displayed). Subsequently, the following is displayed: |
|
| DISARMED BYPASS Ready to Arm |
ONE SHORT BEEP | SYSTEM IS IN TEST MODE | Opened Zone identifications will appear. |
(once every 15 |
|
|
sec.) Keypad only |
|
|
TWO SHORT BEEPS | SYSTEM IS ABOUT TO | Opened Zone identifications will appear. |
(once every 5 sec.) | AUTOMATICALLY EXIT TEST |
|
Keypad only | MODE |
|
ONE BEEP | LOW BATTERY AT A | LO BAT displayed with description of transmitter. |
(every 60 sec.) | TRANSMITTER |
|
Keypad only |
|
|
TWO SHORT BEEPS | ARM AWAY OR MAXIMUM | ARMED AWAY or ARMED MAXIMUM is displayed. Red |
Keypad only |
| ARMED indicator is lit. |
THREE SHORT | a. ARM STAY OR INSTANT | a. ARMED STAY ZONE BYPASSED or ARMED |
BEEPS | b. ZONE OPENED WHILE | INSTANT ZONE BYPASSED is displayed. Red |
Keypad only | SYSTEM IS IN CHIME MODE. | ARMED indicator is lit. |
| c. ENTRY WARNING** | b. CHIME displayed, descriptor of open protection zone |
|
| will be displayed if the [✱] key is pressed. |
|
| c. DISARM SYSTEM OR ALARM WILL OCCUR is |
|
| displayed. |
RAPID BEEPING | a. TROUBLE | a. CHECK displayed. Descriptor of troubled protection |
Keypad only | b. AC POWER LOSS ALERT*** | zone is displayed. |
| c. MEMORY OF ALARM | b. AC LOSS displayed (may alternate with other displays |
|
| that may be present). |
|
| c. FIRE or ALARM is displayed; descriptor of zone in |
|
| alarm is displayed. |
SLOW BEEPING | a. ENTRY DELAY WARNING** | a. DISARM SYSTEM OR ALARM WILL OCCUR is |
Keypad only | b. EXIT DELAY WARNING | displayed. Exceeding the delay time without disarming |
| (if programmed) | causes alarm. |
|
| b. ARMED AWAY or ARMED MAXIMUM is displayed |
|
| along with You May Exit Now |
*If bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.
**Entry warning may consist of three short beeps or slow continuous beeping, as programmed by your installer.
***Loss of system battery power is not indicated or annunciated by the keypad (warnings are for loss of AC power only).
–71 –