Hoshizaki KM-1900SRH/3, KM-1900SAH/3, KM-1900SWH/3 instruction manual

Models: KM-1900SWH/3 KM-1900SAH/3 KM-1900SRH/3

1 38
Download 38 pages 3.58 Kb
Page 18
Image 18
8)Carefully remove the thermostat bulb from the thermostat bulb attachment (plastic) of the upper unit.

8)Carefully remove the thermostat bulb from the thermostat bulb attachment (plastic) of the upper unit.

9)Carefully route the thermostat bulb and capillary tubing of the upper unit through the bottom hole of the upper unit. Remove the bushing from the lower bin control thermostat assembly. Route the bulb and tubing through the hole in the assembly and down into the storage bin. Reattach the bushing.

10)Secure the lower bin control thermostat assembly in place with the thumbscrews.

11)Carefully insert the thermostat bulb back into the thermostat bulb attachment (plastic).

12)Secure the thermostat bulb attachment (plastic) of the upper unit to the thermostat bulb attachment (plastic) of the lower unit with the screws of the upper unit. See Fig. 7.

13)Insert the plug of the upper unit into the receptacle of the upper unit's bin control thermostat assembly until it locks into place.

14)Replace the panels and baffle in their correct positions.

Thermostat

Capillary

Tubing

Thermostat Extension Bracket (stainless) or "Z" Bracket (plastic)

Depending on BinThermostat Bulb Attachment Removed from Upper Unit

Thermostat Bulb

Thermostat Bulb

 

Attachment of

Fig. 7

Lower Unit

 

 

 

18

Page 18
Image 18
Hoshizaki KM-1900SRH/3 8Carefully remove the thermostat bulb from the thermostat bulb attachment plastic of the upper unit