b) Connection to a Closed Loop System
•Condenser water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" nominal
ID copper water tubing or equivalent is required for the condenser water supply line.
•Condenser return outlet is 3/8" FPT. A minimum of 3/8" nominal ID copper water tubing or equivalent is required for the condenser return line.
•
•The water supply to the condenser should not drop below 4 GPM.
•The pressure differential between the condenser water supply inlet and condenser return outlet must be no less than 10 PSIG.
•When using a glycol blend, the solution mixture should be less than 30% glycol.
•In order to maintain the proper high side pressure, the condenser water supply inlet temperature should not drop below 45°F (7°C) and the condenser return outlet temperature must be in the 104°F to 115°F (40°C to 46°C) range. Once the icemaker installation is complete, confirm the condenser return outlet temperature 5 minutes after a freeze cycle starts. If the condenser return outlet temperature is not in the proper range, use a flat blade screwdriver to rotate the adjustment screw on the water‑regulating valve until the temperature is in the proper range (rotate counterclockwise to raise temperature or clockwise to lower temperature).
| Minimum 3/8" Nominal | Icemaker Water Supply |
|
| |
| ID Copper Water Tubing | Line |
|
| |
|
|
|
| Icemaker Water Supply | |
Icemaker Water Supply |
| Inlet 1/2" FPT | |||
Line Drain Valve |
|
|
|
| |
|
|
|
|
| Condenser Water |
Condenser Return Outlet 3/8" FPT |
|
| Supply Inlet | ||
|
|
|
|
| 1/2" FPT |
Condenser Water Supply Line | Icemaker |
| |||
|
|
|
| ||
Condenser Return Line |
|
|
| Icemaker | |
|
|
|
| ||
|
|
|
| Drain Outlet | |
|
|
|
|
| |
Minimum 3/8" Nominal |
|
|
| 3/4" FPT | |
|
|
|
| ||
ID Copper Water Tubing |
|
|
|
| |
Condenser Return Line Drain Valve |
|
| Condensation | ||
|
| Drain Outlet | |||
Separate piping to approved |
|
| Vent Tube | Bin | 3/8" OD Hard |
|
| Tube | |||
drain. Leave a 2 inch (5 cm) |
|
|
| ||
| Condenser Water |
|
|
| |
vertical air gap between the |
|
|
|
| |
end of each pipe and the drain. | Supply Line |
|
|
| |
|
| Drain Valve |
|
| Bin Drain Outlet |
|
|
|
| 3/4" FPT | |
|
|
|
|
| |
air gap |
|
|
|
|
|
|
|
| Minimum 3/4" |
|
|
Floor |
|
| Nominal ID Hard Pipe |
| |
|
|
| |||
Drain |
|
| Fig. 19 | ||
Connection To A Closed Loop System |
| ||||
|
|
30