1. Icemaker
•Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" nominal
ID copper water tubing or equivalent is required for the icemaker water supply line.
•An icemaker water supply line
•Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" nominal ID hard pipe or equivalent is required for the icemaker drain line. Condensation drain outlet is 3/8" OD hard tube.
The condensation drain line can be connected to the icemaker drain line or can be run separately.
Icemaker Water Supply Line | Icemaker Water Supply Inlet 1/2" FPT | |
| ||
Minimum 3/8" Nominal |
|
|
ID Copper Water Tubing |
|
|
Icemaker Water Supply Line Drain Valve |
|
|
Remote Condenser Line Set Connections | Icemaker |
|
|
| |
|
| Icemaker |
|
| Drain Outlet |
Vent Tube |
| 3/4" FPT |
|
| |
Bin Drain Outlet |
| Condensation |
| Drain Outlet | |
3/4" FPT | Bin | 3/8" OD Hard |
| Tube | |
Vent Tube |
|
|
Separate piping to approved drain. |
|
|
Leave a 2 inch (5 cm) vertical air gap |
|
|
between the end of each pipe and the |
|
|
drain. |
|
|
Minimum 3/4" |
| |
air gap |
| |
Nominal ID Hard Pipe |
| |
|
|
Floor
DrainKM-1900SAH/3
Fig. 17