Hoshizaki KM-1900SWH/3 instruction manual Icemaker, DrainKM-1900SAH/3 KM-1900SRH/3

Models: KM-1900SWH/3 KM-1900SAH/3 KM-1900SRH/3

1 38
Download 38 pages 3.58 Kb
Page 28
Image 28
1. Icemaker

1. Icemaker

Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" nominal

ID copper water tubing or equivalent is required for the icemaker water supply line.

An icemaker water supply line shut-off valve and drain valve should be installed.

Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" nominal ID hard pipe or equivalent is required for the icemaker drain line. Condensation drain outlet is 3/8" OD hard tube.

The condensation drain line can be connected to the icemaker drain line or can be run separately.

Icemaker Water Supply Line Shut-Off Valve

Icemaker Water Supply Inlet 1/2" FPT

 

Minimum 3/8" Nominal

 

 

ID Copper Water Tubing

 

 

Icemaker Water Supply Line Drain Valve

 

 

Remote Condenser Line Set Connections

Icemaker

 

 

 

 

 

Icemaker

 

 

Drain Outlet

Vent Tube

 

3/4" FPT

 

 

Bin Drain Outlet

 

Condensation

 

Drain Outlet

3/4" FPT

Bin

3/8" OD Hard

 

Tube

Vent Tube

 

 

Separate piping to approved drain.

 

 

Leave a 2 inch (5 cm) vertical air gap

 

 

between the end of each pipe and the

 

 

drain.

 

 

2-inch (5-cm)

Minimum 3/4"

 

air gap

 

Nominal ID Hard Pipe

 

 

 

DrainKM-1900SAH/3Floor

DrainKM-1900SAH/3

KM-1900SRH/3

Fig. 17

28

Page 28
Image 28