F. Electrical Connection

F. Electrical Connection

For All Models WARNING

For All Models

1.Electrical connection must be hard-wired and must meet national, state, and local electrical code requirements. Failure to meet these code requirements could result in death, electric shock, serious injury, fire, or severe damage to equipment.

2.This unit requires an independent power supply. See the nameplate for proper voltage and breaker/fuse size. Failure to use a proper breaker or fuse can result in a tripped breaker, blown fuse, or damage to existing wiring. This could lead to heat generation or fire.

3.THIS UNIT MUST BE GROUNDED. Failure to properly ground this unit could result in death or serious injury.

4.Electrical connection must be made in accordance with the instructions on the "WARNING" tag, provided with the pig tail leads in the junction box. See

Fig. 8a and 8b.

Additional Warnings for Remote Air-Cooled Model

5.THE REMOTE CONDENSER UNIT MUST BE GROUNDED. The power supply and ground wire to the remote condenser unit are supplied from the icemaker. See "II.G.6. Electrical Connection."

6.To reduce the risk of electric shock, make all remote condenser unit connections before connecting the icemaker power supply.

7.On remote air-cooled models, the icemaker should have power for a minimum of 4 hours prior to startup to prevent compressor damage.

Usually an electrical permit and services of a licensed electrician are required.

The maximum allowable voltage variation is ±10 percent of the nameplate rating.