Hoshizaki KM-1900SWH/3, KM-1900SRH/3, KM-1900SAH/3 instruction manual Stacking Condenser Unit

Models: KM-1900SWH/3 KM-1900SAH/3 KM-1900SRH/3

1 38
Download 38 pages 3.58 Kb
Page 26
Image 26
7.Stacking Condenser Unit

1)Remove the louver panel. See Fig. 15.

2)Remove the junction box cover on the remote condenser unit. Remove the fan motor junction box cover on the icemaker.

3)Install a ground wire from the icemaker to the remote condenser unit. Use wire of an appropriate gage and outdoor rating.

4)Install line and neutral wires from the fan motor leads in the icemaker to the leads in the remote condenser unit junction box. Use wire of an appropriate gage and outdoor rating.

5)Replace the junction box covers and the louver panel in their correct positions.

Remote Condenser Unit

 

Junction Box

 

Cover

 

Louver Panel

 

Screws

Fig. 15

 

Icemaker

Fan Motor Junction

Box Cover

Screw

7.Stacking Condenser Unit

1)Install the lower remote condenser unit as described earlier in this section.

2)Place the upper remote condenser unit on top of the lower. See Fig. 16.

3)Secure the upper remote condenser unit to the lower remote condenser unit with the 4 screws provided.

4)Install refrigerant lines and make electrical connection as described earlier in this section.

Upper Remote

Condenser Unit

Screws Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundScrews

Lower Remote

Condenser Unit

Fig. 16