C. Performance Data
1. KM-650MAH (air-cooled)
APPROXIMATE ICE | AMBIENT TEMP. |
|
|
| WATER TEMP. (ºF/ºC) |
|
| ||||||
PRODUCTION PER 24 HR. | (ºF/ºC) |
|
| 50/10 |
|
| 70/21 |
|
| 90/32 | |||
|
|
|
| 70/21 |
| 589 | 267 |
| 566 | 257 |
| 526 | 238 |
|
|
|
| 80/27 |
| 572 | 259 |
| 537 | 243 |
| 490 | 222 |
|
|
|
| 90/32 |
| 566 | 257 |
| 512 | 232 |
| 467 | 212 |
lbs./day |
| kg./day | 100/38 |
| 555 | 252 |
| 501 | 227 |
| 426 | 193 | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
APPROXIMATE ELECTRIC | 70/21 |
|
| 1100 |
|
| 1141 |
|
| 1170 | |||
CONSUMPTION | 80/27 |
|
| 1131 |
|
| 1195 |
|
| 1209 | |||
|
|
|
| 90/32 |
|
| 1141 |
|
| 1240 |
|
| 1261 |
watts |
|
|
| 100/38 |
|
| 1138 |
|
| 1245 |
|
| 1280 |
APPROXIMATE WATER | 70/21 |
| 257 | 0.97 |
| 214 | 0.81 |
| 190 | 0.72 | |||
CONSUMPTION PER 24 HR. | 80/27 |
| 224 | 0.85 |
| 156 | 0.59 |
| 153 | 0.58 | |||
|
|
|
| 90/32 |
| 214 | 0.81 |
| 108 | 0.41 |
| 95 | 0.36 |
gal./day |
| m3/day | 100/38 |
| 163 | 0.62 |
| 105 | 0.40 |
| 84 | 0.32 | |
FREEZING CYCLE TIME | 70/21 |
|
| 30 |
|
| 32 |
|
| 35 | |||
|
|
|
| 80/27 |
|
| 31 |
|
| 35 |
|
| 38 |
|
|
|
| 90/32 |
|
| 32 |
|
| 37 |
|
| 40 |
min. |
|
|
| 100/38 |
|
| 33 |
|
| 38 |
|
| 43 |
HARVEST CYCLE TIME | 70/21 |
|
| 4.6 |
|
| 3.9 |
|
| 3.6 | |||
|
|
|
| 80/27 |
|
| 4.1 |
|
| 3.0 |
|
| 3.0 |
|
|
|
| 90/32 |
|
| 3.9 |
|
| 2.2 |
|
| 2.1 |
min. |
|
|
| 100/38 |
|
| 3.1 |
|
| 2.2 |
|
| 2.0 |
HEAD PRESSURE | 70/21 |
| 225 | 15.8 |
| 246 | 17.3 |
| 270 | 19.0 | |||
|
|
|
| 80/27 |
| 241 | 17.0 |
| 275 | 19.3 |
| 295 | 20.7 |
|
|
|
| 90/32 |
| 246 | 17.3 |
| 298 | 21.0 |
| 320 | 22.5 |
PSIG | kg/cm2G | 100/38 |
| 249 | 17.5 |
| 303 | 21.3 |
| 341 | 24.0 | ||
SUCTION PRESSURE | 70/21 |
| 53 | 3.7 |
| 55 | 3.9 |
| 58 | 4.1 | |||
|
|
|
| 80/27 |
| 54 | 3.8 |
| 57 | 4.0 |
| 61 | 4.3 |
|
|
|
| 90/32 |
| 55 | 3.9 |
| 59 | 4.2 |
| 63 | 4.4 |
PSIG | kg/cm2G | 100/38 |
| 56 | 3.9 |
| 60 | 4.2 |
| 67 | 4.7 | ||
TOTAL HEAT OF REJECTION FROM CONDENSER |
| 10,600 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] |
Note:
1.Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold should be used for reference only.
2.We reserve the right to make changes in specifications and design without prior notice.
28