Hoshizaki KM-650MWH, KM-650MAH, KM-650MRH service manual Problem Possible Cause Remedy

Models: KM-650MWH KM-650MRH KM-650MAH

1 54
Download 54 pages 14.7 Kb
Page 35
Image 35

Problem

Possible Cause

 

Remedy

 

 

 

 

[5] No water comes from

c) Water System

2. Clogged.

2. Clean.

spray tubes. Water

(continued)

 

 

3. Pump out check valve

3. Check assembly and

pump will not start, or

 

 

leaking by.

clean.

freeze cycle time is

 

 

 

 

d)Pump Motor

1. Motor winding opened.

1. Replace.

too short. (continued)

 

 

 

 

 

 

2. Bearing worn out.

2. Replace.

 

 

 

 

 

 

3. Wiring to pump motor.

3. Check for loose

 

 

 

connection or open, and

 

 

 

replace.

 

 

 

 

 

 

4. Defective capacitor.

4. Replace.

 

 

 

 

 

 

5. Defective or bound

5. Replace and clean.

 

 

impeller.

 

 

 

 

 

 

 

6. Mechanical seal worn

6. Check and replace.

 

 

out.

 

 

 

 

 

 

e)Control Board

1. Defective.

1. See "II.C.4. Control Board

 

 

 

Check Procedure."

 

 

 

 

[6] Fan motor will

a)Fan Motor

1. Motor winding opened.

1. Replace.

not start, or is not

 

 

 

operating.

 

2. Bearing worn out.

2. Replace.

 

 

 

 

 

 

3. Wiring to fan motor.

3. Check for loose

 

 

 

connection or open, and

 

 

 

replace.

 

 

 

 

 

 

4. Defective capacitor.

4. Replace.

 

 

 

 

 

 

5. Fan blade bound.

5. Check and replace.

 

 

 

 

 

b)Control Board

1. Defective.

1. See "II.C.4. Control Board

 

 

 

Check Procedure."

 

 

 

 

[7] All components

a)Refrigerant

1. Undercharged.

1. Check for leaks and

run, but no ice is

 

 

recharge.

produced.

 

 

 

 

2. Air or moisture

2. Replace drier and

 

 

 

 

trapped.

recharge.

 

 

 

 

 

b)Compressor

1. Defective valve.

1. Replace.

 

 

 

 

 

c) Hot Gas Valve

1. Continues to open in

1. Check and replace.

 

 

freeze cycle.

 

 

 

 

 

 

d)Line Valve

1. Continues to close in

1. Check and replace.

 

 

freeze cycle.

 

 

 

 

 

 

e)Inlet Water Valve

1. Water valve is wide

1. Check for water leaks with

 

 

open during freeze.

icemaker off.

 

 

 

 

 

f) Headmaster (C.P.R.)

1. Not operating properly

1. Replace headmaster.

 

(Remote Unit)

and liquid line

 

 

 

temperature too warm.

 

 

 

 

 

 

g)Water Supply Line

1. Condenser water

1. Check and get

 

(water-cooled model

pressure too low or off

recommended pressure.

 

only)

and pressure control

 

 

 

opens and closes

 

 

 

frequently.

 

 

 

 

 

 

h)Water Regulator

1. Set too high.

1. Adjust or replace. See

 

(water-cooled model

 

"V.I. Adjustment of Water

 

only)

 

Regulating Valve."

 

 

 

 