Hoshizaki KM-650MAH, KM-650MRH, KM-650MWH service manual Evaporator is Frozen Up

Models: KM-650MWH KM-650MRH KM-650MAH

1 54
Download 54 pages 14.7 Kb
Page 36
Image 36

2. Evaporator is Frozen Up

Problem

Possible Cause

 

Remedy

 

 

 

 

[1]Freeze cycle time is

a)Float Switch

1. Leads short-circuit or

1. Check and replace.

too long.

 

defective switch.

 

 

 

 

 

 

 

2. Float does not move

2. Clean or replace.

 

 

freely.

 

 

 

 

 

 

b)Inlet Water Valve

1. Diaphragm does not

1. Check for water leaks with

 

 

close.

icemaker off.

 

 

 

 

 

c) Control Board

1. Defective.

1. See "II.C.4. Control Board

 

 

 

Check Procedure."

 

 

 

 

[2]All ice formed on

a)Evaporator

1. Scaled up.

1. Clean.

evaporator does not

 

 

 

b)Water Supply Line

1. Water pressure too

1. Check and get

fall into bin in harvest

cycle.

 

low.

recommended pressure.

c) Water Filter System

1. Dirty/Restricted

1. Replace filter.

 

 

 

 

 

 

d)Inlet Water Valve

1. Dirty mesh filter or

1. Clean.

 

 

orifice.

 

 

 

 

 

 

 

2. Diaphragm does not

2. Check for water leaks with

 

 

close.

icemaker off.

 

 

 

 

 

e) Ambient and/or water

1. Too cool.

1. Increase temperature.

 

temperature.

 

 

 

 

 

 

 

f) Line Valve

1. Continues to open in

1. Check operation in harvest

 

 

harvest cycle.

cycle and replace.

 

 

 

 

 

g)Thermistor

1. Out of position or

1. See "V.I. Removal

 

 

loose attachment.

and Replacement of

 

 

 

Thermistor."

 

 

 

 

 

h)Control Board

1. Harvest timer is set

1. Adjust longer, referring

 

 

too short.

to "II.C.3. Controls and

 

 

 

Adjustments, c) Harvest

 

 

 

Timer.

 

 

 

 

 

 

2. Defective.

2. See "II.C.4. Control Board

 

 

 

Check Procedure."

 

 

 

 

[3]Other

a)Spray Tubes

1. Clogged.

1. Clean

 

 

 

 

 

 

2. Out of position.

2. Place in position.

 

 

 

 

 

b)Water System

1. Dirty.

1. Clean.

 

 

 

 

 

c) Refrigerant

1. Undercharged.

1. Check for leaks and

 

 

 

recharge.

 

 

 

 

 

d)Expansion Valve

1. Bulb out of position or

1. Place in position.

 

 

loose attachment.

 

 

 

 

 

 

 

2. Defective.

2. Replace.

 

 

 

 

 

e)Hot Gas Valve

1. Coil winding opened.

1. Replace.

 

 

 

 

 

 

2. Plunger does not

2. Replace.

 

 

move.

 

 

 

 

 

 

 

3. Wiring to hot gas

3. Check for loose

 

 

valve.

connection or open, and

 

 

 

replace.

 

 

 

 

 

f) Ice Cube Guide

1. Out of position and ice

1. Place in position.

 

 

trapped.

 

 

 

 

 

36

Page 36
Image 36
Hoshizaki KM-650MAH, KM-650MRH, KM-650MWH service manual Evaporator is Frozen Up