Hoshizaki KM-650MRH, KM-650MAH, KM-650MWH service manual Problem Possible Cause Remedy

Models: KM-650MWH KM-650MRH KM-650MAH

1 54
Download 54 pages 14.7 Kb
Page 34
Image 34

Problem

Possible Cause

 

Remedy

 

 

 

 

[1] The icemaker will not

m)Interlock Switch

1. OFF position.

1. Move to ON position.

start. (continued)

(Cleaning Valve)

 

 

 

 

 

 

 

 

2. Bad contacts.

2. Check for continuity and

 

 

 

replace.

 

 

 

 

 

n)Wash Switch

1. WASH position.

1. Move to ICE position.

 

 

 

 

 

 

2. Bad contacts.

2. Check and replace.

 

 

 

 

[2] Water continues to

a)Float Switch

1. Connector

1. Place in position.

be supplied, and the

 

disconnected.

 

icemaker will not

 

 

 

 

2. Leads opened or

2. Check and replace.

start.

 

 

defective switch.

 

 

 

 

 

 

 

 

 

 

3. Float does not move

3. Clean or replace.

 

 

freely.

 

 

 

 

 

 

b)Control Board

1. Defective.

1. Replace.

 

 

 

 

[3] Compressor will

a)Magnetic Contactor

1. Bad contacts.

1. Check for continuity and

not start or stops

 

 

replace.

operating.

 

 

 

 

2. Coil winding opened.

2. Replace.

 

 

 

 

 

 

 

b)Start Capacitor or Run

1. Defective.

1. Replace.

 

Capacitor

 

 

 

 

 

 

 

c) Internal Overload

1. Loose terminal.

1. Tighten or replace.

 

Protector Open (check

 

 

 

1 through 3 to the right

2. Voltage.

2. Check and correct.

 

and d through f below)

 

 

 

3. Dirty condenser.

3. Clean.

 

 

 

 

 

d)Starter

1. Bad contacts.

1. Check and replace.

 

 

 

 

 

 

2. Coil winding opened.

2. Replace.

 

 

 

 

 

e)Compressor

1. Wiring to compressor.

1. Check for loose

 

 

 

connection or open, and

 

 

 

replace.

 

 

 

 

 

 

2. Defective.

2. Replace.

 

 

 

 

 

 

3. Protector tripped.

3. Reduce temperature.

 

 

 

 

 

f) Control Board

1. No power to contactor.

1. See "II.C.4. Control Board

 

 

 

Check Procedure."

 

 

 

 

[4] Water continues to

a)Inlet Water Valve

1. Diaphragm does not

1. Check for water leaks with

be supplied in freeze

 

close.

icemaker off.

cycle.

 

 

 

b)Control Board

1. Defective.

1. See "II.C.4. Control Board

 

 

 

 

Check Procedure."

 

 

 

 

[5] No water comes from

a)Water Supply Line

1. Water pressure too

1. Check and get

spray tubes. Water

 

low and water level in

recommended pressure.

pump will not start, or

 

water tank too low.

 

freeze cycle time is

 

 

 

b)Inlet Water Valve

1. Dirty mesh filter or

1. Clean.

too short.

 

orifice and water level

 

 

 

 

 

 

in water tank too low.

 

 

 

 

 

 

c) Water System

1. Water leaks.

1. Check connections for

 

 

 

water leaks, and replace.

 

 

 

 

34

Page 34
Image 34
Hoshizaki KM-650MRH, KM-650MAH, KM-650MWH service manual Problem Possible Cause Remedy