Problem | Possible Cause |
| Remedy | |
|
|
|
| |
[1] The icemaker will not | m)Interlock Switch | 1. OFF position. | 1. Move to ON position. | |
start. (continued) | (Cleaning Valve) |
|
| |
|
|
|
| |
|
| 2. Bad contacts. | 2. Check for continuity and | |
|
|
| replace. | |
|
|
|
| |
| n)Wash Switch | 1. WASH position. | 1. Move to ICE position. | |
|
|
|
| |
|
| 2. Bad contacts. | 2. Check and replace. | |
|
|
|
| |
[2] Water continues to | a)Float Switch | 1. Connector | 1. Place in position. | |
be supplied, and the |
| disconnected. |
| |
icemaker will not |
|
|
| |
| 2. Leads opened or | 2. Check and replace. | ||
start. |
| |||
| defective switch. |
| ||
|
|
| ||
|
|
|
| |
|
| 3. Float does not move | 3. Clean or replace. | |
|
| freely. |
| |
|
|
|
| |
| b)Control Board | 1. Defective. | 1. Replace. | |
|
|
|
| |
[3] Compressor will | a)Magnetic Contactor | 1. Bad contacts. | 1. Check for continuity and | |
not start or stops |
|
| replace. | |
operating. |
|
|
| |
| 2. Coil winding opened. | 2. Replace. | ||
|
| |||
|
|
|
| |
| b)Start Capacitor or Run | 1. Defective. | 1. Replace. | |
| Capacitor |
|
| |
|
|
|
| |
| c) Internal Overload | 1. Loose terminal. | 1. Tighten or replace. | |
| Protector Open (check |
|
| |
| 1 through 3 to the right | 2. Voltage. | 2. Check and correct. | |
| and d through f below) |
|
| |
| 3. Dirty condenser. | 3. Clean. | ||
|
|
|
| |
| d)Starter | 1. Bad contacts. | 1. Check and replace. | |
|
|
|
| |
|
| 2. Coil winding opened. | 2. Replace. | |
|
|
|
| |
| e)Compressor | 1. Wiring to compressor. | 1. Check for loose | |
|
|
| connection or open, and | |
|
|
| replace. | |
|
|
|
| |
|
| 2. Defective. | 2. Replace. | |
|
|
|
| |
|
| 3. Protector tripped. | 3. Reduce temperature. | |
|
|
|
| |
| f) Control Board | 1. No power to contactor. | 1. See "II.C.4. Control Board | |
|
|
| Check Procedure." | |
|
|
|
| |
[4] Water continues to | a)Inlet Water Valve | 1. Diaphragm does not | 1. Check for water leaks with | |
be supplied in freeze |
| close. | icemaker off. | |
cycle. |
|
|
| |
b)Control Board | 1. Defective. | 1. See "II.C.4. Control Board | ||
| ||||
|
|
| Check Procedure." | |
|
|
|
| |
[5] No water comes from | a)Water Supply Line | 1. Water pressure too | 1. Check and get | |
spray tubes. Water |
| low and water level in | recommended pressure. | |
pump will not start, or |
| water tank too low. |
| |
freeze cycle time is |
|
|
| |
b)Inlet Water Valve | 1. Dirty mesh filter or | 1. Clean. | ||
too short. | ||||
| orifice and water level |
| ||
|
|
| ||
|
| in water tank too low. |
| |
|
|
|
| |
| c) Water System | 1. Water leaks. | 1. Check connections for | |
|
|
| water leaks, and replace. | |
|
|
|
|
34