3. KM-650MRH (remote air-cooled)

APPROXIMATE ICE

AMBIENT TEMP.

 

 

WATER TEMP. (ºF/ºC)

 

 

PRODUCTION PER 24 HR.

(ºF/ºC)

 

50/10

 

 

70/21

 

 

90/32

 

 

 

 

70/21

615

279

 

597

271

 

556

252

 

 

 

 

80/27

601

273

 

574

260

 

523

237

 

 

 

 

90/32

597

271

 

554

251

 

506

230

lbs./day

 

kg./day

100/38

583

264

 

543

246

 

462

210

 

 

 

 

 

 

 

 

 

 

 

 

APPROXIMATE ELECTRIC

70/21

 

1150

 

 

1179

 

 

1212

CONSUMPTION

80/27

 

1172

 

 

1218

 

 

1247

 

 

 

 

90/32

 

1179

 

 

1250

 

 

1281

watts

 

 

 

100/38

 

1183

 

 

1257

 

 

1310

APPROXIMATE WATER

70/21

266

1.01

 

220

0.83

 

198

0.75

CONSUMPTION PER 24 HR.

80/27

231

0.87

 

161

0.61

 

160

0.61

 

 

 

 

90/32

220

0.83

 

111

0.42

 

100

0.38

gal./day

 

m3/day

100/38

169

0.64

 

108

0.41

 

91

0.34

FREEZING CYCLE TIME

70/21

 

29

 

 

31

 

 

33

 

 

 

 

80/27

 

30

 

 

33

 

 

36

 

 

 

 

90/32

 

31

 

 

34

 

 

37

min.

 

 

 

100/38

 

32

 

 

35

 

 

40

HARVEST CYCLE TIME

70/21

 

4.6

 

 

3.8

 

 

3.6

 

 

 

 

80/27

 

4.0

 

 

2.8

 

 

3.0

 

 

 

 

90/32

 

3.8

 

 

2.0

 

 

2.0

min.

 

 

 

100/38

 

3.0

 

 

2.0

 

 

2.0

HEAD PRESSURE

70/21

214

15.1

 

233

16.4

 

254

17.8

 

 

 

 

80/27

229

16.1

 

258

18.2

 

275

19.4

 

kg/cm2G

90/32

233

16.4

 

279

19.6

 

298

21.0

PSIG

100/38

235

16.6

 

283

19.9

 

315

22.2

SUCTION PRESSURE

70/21

51

3.6

 

53

3.8

 

56

4.0

 

 

 

 

80/27

53

3.7

 

56

3.9

 

59

4.1

 

 

 

 

90/32

53

3.8

 

58

4.1

 

61

4.3

PSIG

kg/cm2G

100/38

54

3.8

 

59

4.2

 

64

4.5

TOTAL HEAT OF REJECTION FROM CONDENSER

9400 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

TOTAL HEAT OF REJECTION FROM COMPRESSOR

1600 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

CONDENSER VOLUME

40 CU. IN (URC-5F)

Note:

1.Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold should be used for reference only.

2.We reserve the right to make changes in specifications and design without prior notice.

30

Page 30
Image 30
Hoshizaki KM-650MAH, KM-650MRH, KM-650MWH service manual 615