2.Sanitizing Procedure - Following Cleaning Procedure

1)Dilute a 5.25% sodium hypochlorite solution (chlorine bleach) with water (add approximately 0.9 fl. oz. (27 ml) to 1.8 gal. (6.8 lit.) of water).

2)Remove the front insulation.

3)Pour the sanitizing solution into the water tank.

4)Move the service switch to the "WASH" position.

5)Replace the front insulation and the front panel in their correct positions.

6)Turn on the power supply to start the sanitizing process.

7)Turn off the power supply after 15 minutes.

8)Remove the front panel.

9)Move the service switch to the "DRAIN" position.

10)Replace the front panel in its correct position and turn on the power supply for 2 minutes.

11)Turn off the power supply.

12)Remove the front panel.

13)Repeat steps 18 through 31 in "1. Cleaning Procedure" two times to rinse thoroughly.

14)Move the control switch to the "ICE" position.

15)Replace the front panel in its correct position.

16)Clean the storage bin/dispenser unit liner using a neutral cleaner. Rinse thoroughly after cleaning.

17)Turn on the power supply to start the automatic icemaking process.