CONVERTING TO LP GAS
or Converting Back to Natural Gas from LP
HOW TO CONVERT A STANDARD TWIN BURNER RANGE FOR USE WITH LP GAS OR NATURAL GAS
This range was adjusted for Natural or LP gas as specified on the serial plate.
The conversion should be done by a qualified technician or installer.
For gas conversion you will need a 1/2″ open end wrench.
1PREPARE RANGE FOR CONVERSION
(1) Turn off gas supply at the wall.
(2) Turn off the electrical power to the range.
If range has not yet been connected to gas supply, or if flexible connection was made, range may be pulled out from the wall to make conversion easier.
2 CONVERT THE PRESSURE REGULATOR
WARNING: Do not remove the pressure regulator from the range.
1.Locate the pressure regulator in the range.
Pressure regulator location under the cooktop
ACONVERT THE PRESSURE REGULATOR FOR ELECTRIC IGNITION MODELS
Hollow end | Cap | Solid end |
| ||
towards |
| towards |
regulator for |
| regulator for |
Natural gas. |
| LP gas |
Spring
On
switch for
oven only
Off
1.Unscrew the cap from the pressure regulator. Be sure the spring stays in place.
2.Turn the cap toward the desired setting.
3.Replace the cap of the regulator. The letters corresponding with the type of gas being used should be visible on the exposed end of the cap.
(continued next page)
2.Follow the directions in box match your regulator type.
A
or
B
that
35