Hotpoint WD71 Hot and Cold Fill, If you have no hot water supply, Fitting a Cold Fill Adaptor

Models: WD71

1 24
Download 24 pages 14.09 Kb
Page 6
Image 6

WARNING

Do not connect appliance to a single outlet instantaneous water heater.

3. Connect to the Water Supply...

Incoming hot and cold water pressure should be between 3 and 150 psi (21 - 1034 Kpa).

The temperature of the incoming household hot water supply should ideally be 60°C and no higher than 70°C as this could cause damage to both your laundry and appliance.

The water supply taps must be easily accessible when the appliance is installed.

The appliance must be connected to the appliance water supply using the new hose set supplied, old hose sets should not be used.

Hot and Cold Fill

1.Connect straight end of supplied red or grey hose to the HOT water supply tap (Fig 1). Connect straight end of supplied blue hose to the COLD water supply tap.

2.Hand tighten connectors sufficiently to ensure water does not leak from the hose connections.

3.Before connecting each of the hoses to the appliance,

confirm water supply is flowing by holding the free end

of each hose in a bucket, turn the relevant water supplyFig 1 taps on and then off.

4.Connect angled end of red or grey hose to white plastic inlet valve marked ‘H’ (Fig 2) and angled end of blue hose to white plastic inlet valve marked ‘C’ at the back of the appliance.

5.Hand tighten connectors sufficiently to ensure water does not leak from the hose connections.

6.Turn on water supply taps and check for leaks from the connectors. In the event of a leak, turn off supply tap, remove connector and check sealing washer is in place.

Fig 2

Refit connector and tighten. Turn on water supply taps.

Cold Water Supply

Remember you may be charged for a service call if a problem with your appliance is caused by incorrect installation or misuse.

If you have no hot water supply...

A Cold Fill Adaptor (Fig 3) is available from your local Hotpoint authorised Service Centre or by calling the Genuine Parts & Accessories Mail Order Hotline

UK: 08709 077 077 or Republic of Ireland: (01) 842 6836.

Fitting a Cold Fill Adaptor

1.Connect straight ends of supplied hoses to the Cold Fill Adaptor (Fig 3).

2.Connect adaptor to the cold water supply tap (Fig 4).

3.Before connecting the hoses to the appliance hold the free end of each hose in a bucket, gently turn on the tap to confirm the water supply is flowing. Turn off the tap.

4.Connect angled end of the supplied hoses to white plastic inlet valves marked ‘H’ and ‘C’ at the back of the appliance.

5.Hand tighten the connectors sufficiently to ensure water does not leak from the hose connections. Turn on water supply taps.

Inlet to machine

Fig. 3

Inlet to machine

Fig. 4

6

Page 6
Image 6
Hotpoint WD71 instruction manual Hot and Cold Fill, If you have no hot water supply, Fitting a Cold Fill Adaptor