| bit: | 7 | 6 |
| 5 |
| 4 | 3 | 2 | 1 | 0 |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| D | LC |
| R |
| B | M | L | LE | CR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| ||||||||
|
|
|
| Left Hex Digit |
| Right Hex Digit |
|
| |||||||
| where: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| |||||||||||
| D = 1 | Packet was deferred from transmission for a period that |
| ||||||||||||
|
| exceeded firmware timeout (about 1 second). (Trace packet) |
| ||||||||||||
|
|
|
|
| |||||||||||
| LC = 1 | Lost carrier sense on transmit packet. (Trace packet) |
| ||||||||||||
|
|
|
|
| |||||||||||
| R = 1 | Packet collision retry limit was exceeded. (Trace packet) |
| ||||||||||||
|
|
|
|
| |||||||||||
| B = 1 | Babble error. The Link Controller chip detected the |
| ||||||||||||
|
| transmit packet exceeded the maximum allowed packet length |
| ||||||||||||
|
| (1518 bytes, excluding the Preamble and Start of F rame |
| ||||||||||||
|
| Delimiter fields). (Trace packet) |
|
|
|
| |||||||||
|
|
|
|
| |||||||||||
| M = 1 | Card memory subsystem error. (Trace packet) |
| ||||||||||||
|
|
|
|
| |||||||||||
| L = 1 | On packet transmit, a late collision occurred. |
| ||||||||||||
|
| (Trace packet) |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
| |||||||||||
| LE = 1 | Received packet contained a length field error. |
| ||||||||||||
|
| (Bad packet) |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
| |||||||||||
| CR = 1 | Received packet contained a CRC error. (Bad packet) |
| ||||||||||||
|
|
|
|
|
|
| |||||||||
| All bits = 0 |
|
|
| No destination program for receive packet. (Orphan) |
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Figure 5%1. Deciphering the Packet Error Byte, ERR#
In accordance with the IEEE 802.2 Standard, common CTRL parameter values are shown in Table 5"10 (see Chapter 2 for a review of a packet's Control field).
Table 5%10. IEEE 802.2 Control Field Designations
CTRL Parameter* | Information Field Description |
|
|
03 or 13 hex | Unnumbered Information |
|
|
AF or BF hex | XID Loopback Packet Data |
|
|
E3 or F3 hex | TEST Loopback Packet Data |
|
|
*Note: Two values, depending on the P/F bit of the control Field (see Chapter 2).
List Facility
The returned information from an RE command may exceed a single terminal screen display. If the event log file is large, it may be viewed using a •list facility" very similar to the standard RTE"A list facility. Pressing any key other than <A> or <RETURN> will display another full screen. Pressing <A> will abort.
Using Node Manager 5%49