Models: 2215AP 2218AP 2224AP 2225AP 2203AP 2219AP 2227US 2201AP 2243AP 2214AP 2217AP 2226CL 2212AP 2209CL 2236CL 2262AP 2256AP 2216AP 2222AP 2231AP 2265AP 2208AP 2204AP 2245AP 2254AP 2264AP 2266AP 2268AP 2270AP 2202XX 2206AL 2244AP 2249AP 2250AP 2257AP 2211AP 2201XX 2204US 2248AP 2251AP 2231US 2261AP 2267AP 2200LA 2242AP 2260AP 2210US 2229AP 2203AS 2233AP 2246AP 2253AP 2232US 2230AP 2210AP 2206US 2239AP 2228AP 2204AS 2236AP 2247AP 2258AP 2235AP 2223US 2269AP 2208AS 2203AL 2200 2255AP 2218RS 2201US 2204AL 2221AP 2206AP 2213AP

1 197
Download 197 pages 59.19 Kb
Page 87
Image 87

Removal and Replacement Preliminaries

4.7Grounding Equipment and Methods

Grounding equipment must include either a wrist strap or a foot strap at a grounded workstation.

When seated, wear a wrist strap connected to a grounded system. Wrist straps are flexible straps with a minimum of one megohm ±10% resistance in the ground cords. To provide proper ground, wear a strap snugly against the skin at all times. On grounded mats with banana-plug connectors, use alligator clips to connect a wrist strap.

When standing, use foot straps and a grounded floor mat. Foot straps (heel, toe, or boot straps) can be used at standing workstations and are compatible with most types of shoes or boots. On conductive floors or dissipative floor mats, use foot straps on both feet with a minimum of one megohm resistance between the operator and ground. To be effective, the conductive strips must be worn in contact with the skin.

Other grounding equipment recommended for use in preventing electrostatic damage includes:

Antistatic tape

Antistatic smocks, aprons, and sleeve protectors

Conductive bins and other assembly or soldering aids

Nonconductive foam

Conductive tabletop workstations with ground cords of one megohm resistance

Static-dissipative tables or floor mats with hard ties to the ground

Field service kits

Static awareness labels

Material-handling packages

Nonconductive plastic bags, tubes, or boxes

Metal tote boxes

Electrostatic voltage levels and protective materials