Removal and replacement procedures

Static awareness labels

Material-handling packages

Nonconductive plastic bags, tubes, or boxes

Metal tote boxes

Electrostatic voltage levels and protective materials

The following table lists the shielding protection provided by antistatic bags and floor mats.

Material

Use

Voltage protection level

 

 

 

Antistatic plastic

Bags

1,500 V

 

 

 

Carbon-loaded plastic

Floor mats

7,500 V

 

 

 

Metallized laminate

Floor mats

5,000 V

 

 

 

Unknown user password

If the computer you are servicing has an unknown user password, follow these steps to clear the password:

These steps also clear CMOS.

1.Shut down the computer. If you are unsure whether the computer is off or in Hibernation, turn the computer on, and then shut it down through the operating system.

2.Disconnect all external devices connected to the computer.

3.Disconnect the power from the computer by first unplugging the power cord from the AC outlet and then unplugging the AC adapter from the computer.

4.Remove the battery (see “Battery” on page 4-8).

5.Remove the real-time clock (RTC) battery (see “RTC battery” on page 4-23).

6.Wait approximately 5 minutes.

7.Replace the RTC battery and reassemble the computer.

8.Connect AC power to the computer. Do not reinsert any batteries at this time.

9.Turn on the computer.

All passwords and all CMOS settings have been cleared.