Configuring Advanced Threat Protection

Using the Instrumentation Monitor

Viewing the Current Instrumentation Monitor

Configuration

The show instrumentation monitor configuration command displays the config-

ured thresholds for monitored parameters.

ProCurve# show instrumentation

monitor configuration

PARAMETER

LIMIT

-------------------------

---------------

mac-address-count

1000 (med)

ip-address-count

1000 (med)

system-resource-usage

50

(med)

system-delay

5 (high)

mac-moves/min

100

(med)

learn-discards/min

100

(med)

ip-port-scans/min

10

(med)

arp-requests/min

100

(low)

login-failures/min

10

(med)

port-auth-failures/min

10

(med)

SNMP trap generation for alerts: enabled

Instrumentation monitoring log : enabled

Figure 8-10. Viewing the Instrumentation Monitor Configuration

An alternate method of determining the current Instrumentation Monitor configuration is to use the show run command. However, the show run command output does not display the threshold values for each limit set.

8-37