HP A4800A manual Target operation conditions have Changed

Models: A4800A

1 64
Download 64 pages 36.27 Kb
Page 57
Image 57

 

 

 

SCSI Sense Codes

Table A-3

SCSI Additional Sense Code/Qualifier Code Pairs (Continued)

 

 

 

 

 

 

SCSI

SCSI

 

 

 

Addition

 

 

 

Qualifier

Meaning

 

 

al Sense

 

 

Code

 

 

 

Code

 

 

 

 

 

 

 

 

 

 

 

 

0x3f

0x00

Target operation conditions have

 

 

 

 

changed

 

 

 

 

 

 

 

 

0x01

Microcode has been changed

 

 

 

 

 

 

 

 

0x02

Changed operating definition

 

 

 

 

 

 

 

 

0x03

Inquiry data has changed

 

 

 

 

 

 

 

0x40

0x00

RAM failure

 

 

 

 

 

 

 

 

nn

Diagnostic failure on component nn

 

 

 

 

 

 

 

0x41

0x00

Data path failure

 

 

 

 

 

 

 

0x42

0x00

Power-on or self-test failure

 

 

 

 

 

 

 

0x43

0x00

Message error

 

 

 

 

 

 

 

0x44

0x00

Internal target failure

 

 

 

 

 

 

 

0x45

0x00

Select or reselect failure

 

 

 

 

 

 

 

0x46

0x00

Unsuccessful soft reset

 

 

 

 

 

 

 

0x47

0x00

SCSI parity error

 

 

 

 

 

 

 

0x48

0x00

Initiator detected error message received

 

 

 

 

 

 

 

0x49

0x00

Invalid message error

 

 

 

 

 

 

 

0x4a

0x00

Command phase error

 

 

 

 

 

 

 

0x4b

0x00

Data phase error

 

 

 

 

 

 

 

0x4c

0x00

Logical unit failed self-configuration

 

 

 

 

 

 

 

0x4e

0x00

Overlapped commands attempted

 

 

 

 

 

 