Appendix C: File Level and Application Level Parameters
Appendix C: File Level and Application Level ParametersThe following section presents an overview of the File level and the Application level parameters.
Table 1 File Level Parameters |
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| File Level Parameters |
|
| Data Type |
|
| Default Value |
|
| Minimum |
|
| Maximum | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Accuracy |
|
| Integer |
| 1 |
|
| 1 |
|
| 4 |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RSSI Calibration |
|
|
| Integer |
|
|
|
|
|
|
|
|
| 40 dB |
| ||
|
|
|
|
|
|
|
|
|
|
| ||||||||
| Spillage Factor |
|
| Positive Integer |
| 2 |
|
| 2 |
|
| 3 |
| |||||
|
|
|
|
|
|
|
|
|
|
| ||||||||
| Min Attenuation Factor |
|
|
| Real |
|
|
| 2 |
|
|
| 1.6 |
|
|
| 4 |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
| Max Attenuation Factor |
|
| Real |
| 2 |
|
| 1.6 |
|
| 4 |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
| Alpha |
|
|
| Real |
|
|
|
|
|
| Not applicable |
|
|
| Not applicable |
| |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
| Beta |
|
|
| Real |
|
|
| 0.08 |
|
|
| Not applicable |
|
|
| Not applicable |
|
Table 2 Application Level Parameters |
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Application Level |
|
| Data Type |
|
|
| Default Value |
|
|
| Minimum |
|
|
| Maximum |
| |
| Parameters |
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Coverage Estimation |
|
| Integer |
|
|
|
|
|
|
|
|
| |||||
| Thresholds |
|
|
|
|
| dBm |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Sensor Detection |
|
|
| Integer |
|
|
|
|
|
|
|
|
|
| |||
| Threshold |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| ||||||||
| Sensor Redundancy |
|
| Integer |
| 1 |
|
| 1 |
|
| 10 |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Sensor Prevention |
|
|
| Integer |
|
|
|
|
|
|
|
|
|
| |||
| Thresholds |
|
|
|
|
|
| (low<medium<high) |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| ||||||||
| Device Transmit Power |
|
|
| Integer |
|
|
| 13 |
|
|
| 0 |
|
|
| 20 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
| Channel View Threshold |
|
| Integer |
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
| ||||||||
| AP Redundancy |
|
|
| Integer |
|
|
| 1 |
|
|
| 1 |
|
|
| 10 |
|
In addition to these parameters, Planner also has the following application level parameters:
1Region Settings in ToolsÆSettingsÆPreferencesÆAP Views2Default Access Point Settings
3Auto Channel Select
4‘Do not show this window again’ messages
5Color Palettes
6Report Base Folder
Note: The default installation values are selected when you install a new version of Planner.
110
3Com ® AirProtect Planner User Guide