Valid Keystrokes

Action

 

n/a

The ROM test ignores the keyboard.

 

 

 

Failure Message

Error Code

Meaning

User Aborted

1

User aborted test.

PCMCIA - (PCMCIA.COM)

The PCMCIA test sets up the TI CardBus controller chip, tests IRQ 3, and restores the chip.

DOS Parameter

 

Explanation

0

 

Test lower slot

1 (or any non-0 value)

Test upper slot

 

 

 

Valid Keystrokes

Action

 

n/a

The PCMCIA test ignores the keyboard.

 

 

 

Failure Message

Error Code

Meaning

User Aborted

1

User aborted test.

Failed

2

IRQ fail

Internal IR - (FIRTEST.EXE)

This test performs a minimal test of the IR chip but does not require a second OmniBook. The Full 2 Unit IR test is a more thorough test and does require a second OmniBook (see next section).

DOS Parameter

Explanation

 

Internal

Performs the internal (standalone) test.

 

 

 

Valid Keystrokes

Action

 

n/a

The Internal IR test ignores the keyboard.

 

 

 

Failure Message

Error Code

Meaning

Must clean boot

1

CPU protected mode bit set,

 

 

must clean boot.

Must undock

3

This test cannot run while

 

 

docked. Can also get this

 

 

error if the internal transmit

 

 

failed.

Failed

5

Receive fail or any other fail.

35