Printer Port - (LPT.COM)
NOTE: | This test requires a parallel loopback connector to be connected to the |
| parallel port. |
The Printer Port test checks the data port by writing and reading different bytes 1000 times. The loopback connector is tested by toggling data bits 0 and 1 and seeing if the PE bit gets set. Finally, all of the loopback connections are tested.
DOS Parameter | Explanation |
|
none |
|
|
|
|
|
Valid Keystrokes | Action |
|
n/a | The Printer Port test ignores the keyboard. | |
|
|
|
Failure Message | Error Code | Meaning |
User Aborted | 1 | User aborted test. |
No loopback | 3 | Initial check for loopback |
|
| connector failed. |
No loopback | 4 | Data port test failed. |
No loopback | 5 | Loopback connector test |
|
| failed. |
Hard Disk - (HDC.EXE)
The Hard Disk test verifies the presence of a hard disk, then reads/writes to the sectors. Within the user interface of Diag, pressing the Enter key invokes a short test. The short test check 1% of the cylinders and takes about a minute to complete. Pressing
This checks 100% of the cylinders and takes about 1.5 hours to complete.
DOS Parameter | Explanation |
|
1, none | Only test 1% of the cylinders | |
N | Test N% of the cylinders | |
|
|
|
Valid Keystrokes | Action |
|
Esc | Aborts the test, all other keys flushed. | |
|
|
|
Failure Message | Error Code | Meaning |
User Aborted | 1 | Esc key pressed, or bad hard |
|
| drive |
Failed | 2 | No hard disk |
Failed | 3 | Hard drive controller failed. |