Printer Port - (LPT.COM)

NOTE:

This test requires a parallel loopback connector to be connected to the

 

parallel port.

The Printer Port test checks the data port by writing and reading different bytes 1000 times. The loopback connector is tested by toggling data bits 0 and 1 and seeing if the PE bit gets set. Finally, all of the loopback connections are tested.

DOS Parameter

Explanation

 

none

 

 

 

 

 

Valid Keystrokes

Action

 

n/a

The Printer Port test ignores the keyboard.

 

 

 

Failure Message

Error Code

Meaning

User Aborted

1

User aborted test.

No loopback

3

Initial check for loopback

 

 

connector failed.

No loopback

4

Data port test failed.

No loopback

5

Loopback connector test

 

 

failed.

Hard Disk - (HDC.EXE)

The Hard Disk test verifies the presence of a hard disk, then reads/writes to the sectors. Within the user interface of Diag, pressing the Enter key invokes a short test. The short test check 1% of the cylinders and takes about a minute to complete. Pressing Ctrl-Enter runs the long test.

This checks 100% of the cylinders and takes about 1.5 hours to complete.

DOS Parameter

Explanation

 

1, none

Only test 1% of the cylinders

N

Test N% of the cylinders

 

 

 

Valid Keystrokes

Action

 

Esc

Aborts the test, all other keys flushed.

 

 

 

Failure Message

Error Code

Meaning

User Aborted

1

Esc key pressed, or bad hard

 

 

drive

Failed

2

No hard disk

Failed

3

Hard drive controller failed.

38