Sycard Technology PCCtest 27x/37x software v1.50a Looking for Texas Instruments PCI-1130 PCI Controller…

TI PCI-1130 Found at Bus 00, Function 00, Device 04 TI PCI-1130 Successfully Configured for I/O address

3E0/3E1 Testing Slot 0

Socket Controller = Texas Instruments PCI-1130 Checking Socket Controller…............Passed

Power on delay (Vcc = 5 volt)….........Complete

Basic operational test…................Passed

Data pattern test….....................Passed

Address pattern test…..................Passed

Status bit pattern test…...............Passed

Wait bit test….........................Passed

Reset test…............................Passed

INPACK test…...........................Passed

Card voltage test….....................Passed

Audio out test…........................Complete

Power on delay (Vcc = 3.3 volt)….......Complete

Card voltage test (Vcc = 3.3 volt)…....Passed

Test completed with 0 errors - PASSED

Figure 9 - Sycard Test Results

The OmniBook model F1360 supports zoom video and Cardbus. If a Sycard model 450 PCMCIA socket tester is found (in the upper slot only), a zoom video test will be run on that slot.

Lower PC Card

Level: 2. This test operates like the upper PC card test, but for the lower slot. Manual insertion is generally required to test both slots.

Timers

Level: 2. This test checks that all three system timers are counting correctly, and that the control lines of programmable clock 2 are functioning properly.

Real time clock

Level: 2. This test checks for generation of IRQ0, generation of interrupt 1C, time updates, periodic interrupt, alarm interrupt, and time/date roll-over.

IRQ controller

Level: 2. This test checks the IRQ controllers’ mask register, request register, in-service register, poll command, and EOI commands. Note that Windows prevents testing the poll command.

DMA controller

Level: 2. This test checks the DMA registers and page registers with the pattern registers, then a DMA read/write transfer is tested. Note that Windows prevents testing the DMA controller.

IR port

Level: 2. This test requires a second OmniBook running in fast IR loopback mode. The second OmniBook can be put in fast IR loopback mode either by running Diag with the /F command line option, or by first running Diag then pressing Alt+F. When in loopback mode, all IR data

19