Paw Active

(HP Authorized Service Providers Only)

Required Equipment

Torx #6 screwdriver

5mm hexdriver (F1171 - F1175 only)

Removal Procedure

1.Follow the Logic Board PCA Removal Procedure to gain access to the Paw Active.

2.Remove the Paw Shield. Refer to Figure 42 for location of components.

Paw Shield

(p/n F1170-00009)

Paw Active

(p/n F1170-60909)

Bottom Case (p/n F1170- 60904

F1171 - F1175) (p/n F1360- 60904

Paw Eject Arm

(p/n F1170-40008)

Paw Eject Spring

(p/n F1030-00016)

Figure 42 - Paw Active Removal

3.The Paw Eject Arm and Paw Eject Spring may be removed at this point for convenience.

4.Lift the Paw Active from the plastic posts holding it in place.

Replacement Procedure

1. To replace the Paw Active, reverse the steps in the Removal Procedure.

CAUTION: To avoid damage to the OmniBook components, ensure the paw active flex cable is completely and squarely inserted into the zero insertion force connector.