HP dc73 Blade Client manual Table A-1Specifications

Models: dc73 Blade Client

1 65
Download 65 pages 2.14 Kb
Page 52
Image 52

A Specifications

Table A-1Specifications

Desktop Dimensions

 

 

Height

3.95 in

10.0 cm

Width

13.3 in

33.8 cm

Depth

14.9 in

37.8 cm

 

 

 

Approximate Weight

19 lb

8.6 kg

 

 

 

Weight Supported (maximum distributed load in desktop

77 lb

35 kg

position)

 

 

 

 

 

Temperature Range

 

 

Operating

50° to 95°F

10° to 35°C

Nonoperating

-22° to 140°F

-30° to 60°C

NOTE: Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options installed.

Relative Humidity (noncondensing)

 

 

Operating

10-90%

10-90%

Nonoperating (38.7°C max wet bulb)

5-95%

5-95%

 

 

 

Maximum Altitude (unpressurized)

 

 

Operating

10,000 ft

3048 m

Nonoperating

30,000 ft

9144 m

Heat Dissipation

Maximum (standard PS) Typical (idle; standard PS) Maximum (80 Plus PS) Typical (idle; 80 Plus PS)

1260 BTU/hr

318 kg-cal/hr

307 BTU/hr

77 kg-cal/hr

1,024 BTU/hr

258 kg-cal/hr

239 BTU/hr

60 kg-cal/hr

Power Supply

115V

230V

Operating Voltage Range1

90-264 VAC

90-264 VAC

Rated Voltage Range

100-240 VAC

100-240 VAC

Rated Line Frequency

50-60 Hz

50-60 Hz

 

 

 

Power Output

240 W

240 W

 

 

 

Rated Input Current (maximum)1

 

 

 

 

 