Device Type Register

base + 0216

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Write

 

 

 

 

 

 

 

Undefined

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

 

 

 

 

 

 

 

Model Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Status/Control Register

base + 0416

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Write

 

 

 

Undefined

 

 

X

X

X

TRG

DIR

IRQ

X

CRD

 

 

 

 

 

 

 

 

 

 

 

 

INT

 

EN

 

RST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

 

 

 

Undefined

 

 

1

1

1

BSY*

1

1

IRQ*

IRQ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EN*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Scan Control Register

base + 0616

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Write

 

 

 

Undefined

 

 

X

X

X

RST

CNT

IMM

DBS

CLR

 

 

 

 

 

 

 

 

 

 

 

 

PTR

EN

EN

EN

SCN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

 

 

 

Undefined

 

 

1

1

1

1

CNT

IMM

DBS

CLR

 

 

 

 

 

 

 

 

 

 

 

 

 

EN

EN

EN

SCN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Scan Channel Delay Register

base + 0816

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Write

 

 

 

Undefined

 

 

X

X

X

X

D3

D2

D1

D0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

 

 

 

Undefined

 

 

1

1

1

1

D3

D2

D1

D0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Scan Channel Configuration Register

base + 0A16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Write

VLD*

A_D*

B_D*

C1

C0

X

X

X

X

X

X

X

D3

D2

D1

D0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

 

 

 

 

 

 

 

Undefined

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Direct Channel Configuration Register

base + 0C16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Write

 

 

Undefined

 

 

X

X

X

X

D3

D2

D1

D0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

 

 

 

 

 

 

 

Undefined

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Direct Control Register

base + 0E16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Write

 

 

 

Undefined

 

 

X

X

X

VLD*

A_D*

B_D*

C1

C0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read

 

 

 

 

 

 

 

Undefined

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Appendix B

HP E1351A/53A Register-Based Programming 85