Overview of the Tape Library

Electronics

Electronics

The electronics consists of the control path and robotic cards in the base unit.

Communications include:

Command line interface (CLI) over an RS232 port

Public Ethernet port (The private port is for future use)

Point to point library/tape drive RS232 interface

Control path card for LVD SCSI or SCSI over Fibre Channel

Sensors include:

Card temperature

Fan operational

Power safe

Tape drive present

Tape drive fault LED

RLC Card

The RLC card is the processor card. It contains all the necessary hardware to maintain the robotics, interfaces, servo and vision control, and the door/CAP sensor status.

Interface Cards

The MPW card is the LVD SCSI interface card. The MPU2 card is the Fibre Channel interface card.

Fans

The fans provide cooling for the library electronics. The tape drives and power supplies contain their own fans.

SL500 (M852x) Tape Library Installation and User’s Guide541531-006

1-14