Configuring the M8521 Tape Library for the Integrity | Adding the Control Path and Data Path |
NonStop |
|
To add the data path:
Note. WWN (portname) for each port is labeled on the back of each tape drive.
1.In SCF, issue this command:
SCF> ADD TAPE $tape, SENDTO STORAGE, LOCATION (group, module, slot), SAC
Example:
SCF> ADD TAPE $M8504, SENDTO STORAGE, LOCATION (110,2,2), SAC 2, LUN 0, PORT 50060B00002E69CD
Note. The LUN (logical unit number) for all Fibre Channel tape storage devices directly attached to the NonStop
2.To start the tape drive on the server, issue this command in SCF:
SCF> START TAPE $tape Example:
SCF> START TAPE $M8504
For complete details about the ADD and STATUS commands, including command syntax, see the SCF Reference Manual for the Storage Subsystem.
SL500 (M852x) Tape Library Installation and User’s