460 Using Storage Expert

Rule definitions and attributes

Table 15-2

Rule attributes and default attribute values

 

 

 

 

 

 

Rule

 

Attribute

Default

Description

 

 

 

value

 

 

 

 

 

vxse_redundancy

volume_redundancy

0

Volume redundancy

 

 

 

 

check. The value of 2

 

 

 

 

performs a mirror

 

 

 

 

redundancy check. A

 

 

 

 

value of 1 performs a

 

 

 

 

RAID-5 redundancy

 

 

 

 

check. The default

 

 

 

 

value of 0 performs no

 

 

 

 

redundancy check.

 

 

 

 

 

vxse_rootmir

 

-

-

No user-configurable

 

 

 

 

variables.

 

 

 

 

 

vxse_spares

 

max_disk_spare_ratio

20

Maximum percentage

 

 

 

 

of spare disks in a disk

 

 

 

 

group. Warn if the

 

 

 

 

percentage of spare

 

 

 

 

disks is greater than

 

 

min_disk_spare_ratio

10

this.

 

 

 

 

Minimum percentage

 

 

 

 

of spare disks in a disk

 

 

 

 

group. Warn if the

 

 

 

 

percentage of spare

 

 

 

 

disks is less than this.

 

 

 

 

 

vxse_stripes1

 

default _stripeunit

8k

Stripe unit size for

 

 

 

(8KB)

stripe volumes. Warn if

 

 

 

 

a stripe does not have a

 

 

 

 

stripe unit which is an

 

 

 

 

integer multiple of this

 

 

 

 

value.

 

 

 

 

 

vxse_stripes2

 

too_narrow_stripe

3

Minimum number of

 

 

 

 

columns in a striped

 

 

 

 

plex. Warn if a striped

 

 

 

 

volume has fewer

 

 

 

 

columns than this.

 

 

too_wide_stripe

16

 

 

 

 

 

Maximum number of

columns in a striped plex. Warn if a striped volume has more columns than this.