3. INSTALLATION

IMPORTANT INFORMATION

Pay particular attention not to cross the boundary wire in towards the loop generator/charger.

Joining the boundary wire

If the boundary wire is not long enough and needs to be spliced: Use original solderless coupler. It is waterproof and gives a reliable electrical connection.

To splice: Insert both cable ends in the coupler. Now press down the button on top of the connector fully. Use a pair of pliers or the like, as the button on the connector is difficult to press down by hand.

IMPORTANT INFORMATION

 

Twisted cables, or a screw terminal

 

(chock-block), insulated with insulation tape

 

is not a satisfactory splice. Soil moisture will

 

cause the conductors to oxidise and after a

 

while result in a broken circuit.

3012-535

3012-536

English - 25

Page 24
Image 24
Husqvarna 210 C manual 3012-535