Resetting the Terminal

Troubleshooting and Maintaining the Terminal

4

 

 

3.Scan the Reset Firmware label to restart the firmware and application.

Reset Firmware

*-.*

*-.*

If the terminal or application still will not respond, reset the terminal. For help, continue with the next section.

Resetting the Terminal

If you performed the steps in “Troubleshooting a Locked Up Application” and the terminal or application is locked up and the terminal will not respond to the Reset Firmware command, follow the steps in this section to reset the terminal.

To reset the terminal

Scan the Boot Terminal label to reboot the terminal.

Boot Terminal

*-.1*

*-.1*

If the terminal will not scan, you can perform a destructive reset. A destructive reset can have unpredictable results.

1.If possible, press Fto turn off the terminal.

2.Press and hold the Fkey for approximately 12 seconds. The Good Read LED blinks once and the terminal turns off.

3.Press Fto turn on the terminal. The Boot Menu appears.

4.Press ￿to boot the terminal. Once the terminal has finished booting, your application appears.

5.Set the time and date. For help using the TRAKKER Antares 2400 Menu System, see “Configuring the Terminal With the Menu System” in Chapter 2.