Removal and Replacement Procedures

(GY27-0366) April 3, 2003

Top cover

1.Power OFF the printer by either powering off the terminal or unplugging the external power source from the electrical outlet.

2.Perform the removal procedure for the fiscal interface assembly (see page 6).

3.Remove the two screws from the bottom of the printer.

Figure 4. Removing Two Screws from Base

4.See Figure 5 on page 9. Open the paper cover. Place the top of the screwdriver handle between the side of the printer and the top cover. Then close the top cover on the screwdriver, one side at a time. This frees the pivots on both sides. Slide the paper cover forward and out.

5.Open the ribbon cover using the lift tab. From the right side, push the ribbon cover towards the left side while pressing the lock tab, and remove.

84610 - Kxx Fiscal Printer Service Supplement

Page 28
Image 28
IBM 4610 manual Top cover, Removing Two Screws from Base